* Fri Jan 11 15:22:05 EST 1991 /herschel/h1/rlm/src/test idcsp.f
c
c Moved from temp directory ~/oit/idc 2/19/88 rlm
c changed to a subroutine for plotting DC return currents in mjsanl 
c via call to calanl.
c
      subroutine idcsp(ANS,JTB,JDATA,JNE,LSTAT,JTLMOD,JCLK,
     +TEMP,ipls)
c
C  ********************************************************************
C  *                                                                  *
C  *  PLOT DC RETURN SPECTRA  (Modified for plotting only 2/22/88)    *
C  *                                                                  *
C  *                              RLM 4/06/87                         *
C  *                                                                  *
C  *                                                                  *
C  ********************************************************************
      DIMENSION KTB(6)
      INTEGER*2 JTB(6),JDATA(512),JNE,JTLMOD,JCLK
      COMMON/HEADER/PROJID,FILEID,ISCID,TAPEID(2),IGENDT,IGENTM,FIPID(2)
     1,IFGEND,IFGENT,DPTJ1(2),IFRMT1(2),DPTJ2(2),IFRMT2(2),DPTJ3(2),IFRM
     2T3(2),DPTJ4(2),IFRMT4(2),HSPARE(18)
      DIMENSION ANS(150)
C
C DIMENSION GENERALIZED ARRAYS FOR DC RETURN PLOTS
C
      DIMENSION CIE1(272),CIE2(272),CILA(272),CILD(272)
      DIMENSION CIMA(272),CIMD(272)
      dimension cipla(272),cipld(272),cipma(272),cipmd(272)
      DIMENSION CURPLT(272)
      dimension curnull(272)
C
C CHAN IS A GENERALIZED CHANNEL NUMBER
C   THRESHOLD OF CHAN(1)   IS -5950 V
C   THRESHOLD OF CHAN(273) IS +5950 V
C
      DIMENSION CHAN(273)
      COMMON/CHARHI/CH
C
      DIMENSION YIN(2),YOFF(2)
      REAL*4 YB(2)
      REAL*4 YT(2)
      INTEGER*4 NT(2)
      INTEGER*4 NLT(2)
C
      COMMON/MID/NUMFOR
C     COMMON/PLTSIZ/W,H
      COMMON/RTIM/RCUR(6)
      COMMON/CDATES/SPARA(17),TIMESR(5)
      COMMON/ANSWER/aANS(150),CURRNT(512)
C
C TIME LABELS FOR ALL MODES
C
      DIMENSION TIML(5),TIMM(5),TIME1(5),TIME2(5)
      COMMON/SCID/VOY,IME
C     COMMON/SPEC/SBLK(250)
      COMMON/PLCONS/SPARE(726),CN(4,3),COSB(3),COS2B(3),SIN2B(3)
     *  ,CALCUR(12),CLOCK(3),CAP(2),GAIN(2),V0,ALPHB
     *  ,NQ(4),MASS(4)
C
      REAL*8 TSPEC,TM,TL,TE1,TE2
      LOGICAL LFIRST,LFST
      REAL*4  BARR(129,5)
      DIMENSION TEMP(3)
      data barr/645*0.0/
      DATA LFIRST/.TRUE./,LFST/.TRUE./
      data yb/-8.,4./,yt/-5.,8./
      data nt/15,20/
      data nlt/3,4/
      data preset/1.e15/
      data curnull/272*4.0/
C
C BEGIN EXECUTION
C
      IF (.NOT. LFST) GO TO 2
C------ HERE IS WHERE WE DEFINE OUR PLOT SIZE
      W=11.0
      H=8.5
C------
      CALL CLRTEK
      HT=.0136*H
      CH=.0164*H
      DO 45 I=1,273
      CHAN(I)=I-1.
   45 CONTINUE
      DO 44 I=1,272
      CIE1(I)=0.
      CIE2(I)=0.
      CILA(I)=0.
      CILD(I)=0.
      CIMA(I)=0.
      CIMD(I)=0.
      cipla(i)=0.0
      cipld(i)=0.0
      cipma(i)=0.0
      cipmd(i)=0.0
   44 CONTINUE
      IPRT=6
      TSPEC=0.0
      TM=0.0
      TL=0.0
      TE1=0.0
      TE2=0.0
C
C ALL INITIALIZATIONS COMPLETED
C
      LFST=.FALSE.
  2   CONTINUE
  998 FORMAT (1H ,I10)
      IDSRN=0
      WRITE (6,3)
    3 FORMAT (1H /)
c
c Set up time label information
c
      DO 75 N=1,6
      RCUR(N)=JTB(N)
      KTB(N)=JTB(N)
   75 CONTINUE
      CALL xTYME(KTB,TSPEC)
      IF (JTLMOD .EQ. 1) TL =TSPEC
      IF (JTLMOD .EQ. 2) TM =TSPEC
      IF (JTLMOD .EQ. 3) TE1=TSPEC
      IF (JTLMOD .EQ. 4) TE2=TSPEC
C
C DATA NUMBER TO ENGINEERING UNIT (FEMTOAMPERE) CONVERSION (NO FILTER)
c Conversion done in mjsanl.f and passed via Common block "ANSWER."
C
C CLEAR BARR; SET ALL ELEMENTS TO ZERO
C
      BARR(1,1) = 0.0
      CALL MVC (BARR(1,1),BARR(2,1),2576)
C
C  TRANSFER CURRENTS TO BARR
C
      IF (JTLMOD .LT. 3) GO TO 1800
C
C ELECTRONS IN FIRST 16 ELEMENTS OF CURRNT
C
      DO 2595 K=1,16
      BARR(K,1)=CURRNT(K)
 2595 CONTINUE
      GO TO 1801
C
C MOVE IONS; D-CUP DC RETURN IN I=3, A-CUP DC RETURN IN I=2
C
 1800 DO 495 I=1,4
      DO 595 K=1,JNE
      BARR(K,I)=CURRNT(K+JNE*(I-1))
  595 CONTINUE
  495 CONTINUE
 1801 IME=JNE
      ANE=JNE
C
C WRITE OUT TIME OF SPECTRUM
C
c     CALL YDOYHM(KTB(1),KTB(2),KTB(3),KTB(4),KTB(5)+KTB(6)/1000.)
c     WRITE(IPRT,38) TIMESR
c  38 FORMAT(1H ,'TIME OF CURRENT SPECTRUM IS ',5A4)
      DO 37 I=1,5
      IF (JTLMOD .EQ. 1) TIML(I)=TIMESR(I)
      IF (JTLMOD .EQ. 2) TIMM(I)=TIMESR(I)
      IF (JTLMOD .EQ. 3) TIME1(I)=TIMESR(I)
      IF (JTLMOD .EQ. 4) TIME2(I)=TIMESR(I)
   37 CONTINUE
C
C WRITE OUT TYPE OF DATA
C
c     IF (IPLS .EQ. 3) WRITE (6,910)
c 910 FORMAT (1H 'MODULATOR ON, PLASMA, ** REVERSED SUPPRESSOR **')
c     IF (IPLS .EQ. 15) WRITE (6,911)
c 911 FORMAT (1H 'MODULATOR ON, PLASMA, NORMAL SUPPRESSOR')
c     IF (IPLS .EQ. 13) WRITE (6,912)
c 912 FORMAT (1H 'MODULATOR ON, DC RET, NORMAL SUPPRESSOR')
c     IF (IPLS .EQ. 1) WRITE (6,913)
c 913 FORMAT (1H 'MODULATOR ON, DC RET, ** REVERSED SUPPRESSOR **')
c     IF (IPLS .EQ. 12) WRITE (6,914)
c 914 FORMAT (1H 'MODULATOR * OFF *, DC RET, NORMAL SUPPRESSOR')
c     IF (IPLS .EQ. 0) WRITE (6,915)
c 915 FORMAT (1H 'MODULATOR * OFF *, DC RET, ** REVERSED SUPPRESSOR **')
c 101 CONTINUE
C
C WRITE OUT MODE OF DATA
C
c     IF (JTLMOD .EQ. 1) WRITE (6,916)
c 916 FORMAT (1H ,'L-MODE')
c     IF (JTLMOD .EQ. 2) WRITE (6,917)
c 917 FORMAT (1H ,'M-MODE')
c     IF (JTLMOD .EQ. 3) WRITE (6,918)
c 918 FORMAT (1H ,'E1-MODE')
c     IF (JTLMOD .EQ. 4) WRITE (6,919)
c 919 FORMAT (1H ,'E2-MODE')
C
C OPTION TO WRITE OUT CURRENTS
c (Option is included in mjsanl.f)
C
C
C LOAD UP GENERALIZED RETURN CURRENT ARRAYS
C
      DO 800 I=1,JNE
      IF (JTLMOD .EQ. 3) GO TO 700
      IF (JTLMOD .EQ. 2) GO TO 790
      DO 770 J=1,8
      IF (JTLMOD .EQ. 4) CIE2(8*(I-1)+J)=BARR(17-I,1)
      IF (JTLMOD .EQ. 1) CILA(8*(I-1)+J+144)=BARR(I,2)
      IF (JTLMOD .EQ. 1) CILD(8*(I-1)+J+144)=BARR(I,3)
      IF (JTLMOD .EQ. 1) cipla(8*(I-1)+J+144)=BARR(I,1)
      IF (JTLMOD .EQ. 1) cipld(8*(I-1)+J+144)=BARR(I,4)
  770 CONTINUE
      GO TO 720
C
C M MODE
C
  790 CONTINUE
      CIMA(I+144)=BARR(I,2)
      CIMD(I+144)=BARR(I,3)
      cipma(I+144)=BARR(I,1)
      cipmd(I+144)=BARR(I,4)
      GO TO 720
C
C E1 MODE
C
  700 CONTINUE
      DO 710 J=1,2
      CIE1(2*(I-1)+J+96)=BARR(17-I,1)
  710 CONTINUE
  720 CONTINUE
  800 CONTINUE
C
C  PLOT REAL CURRENTS
C
C ONLY DO PLOT IF THIS IS E1 (LAST IN SEQUENCE)
C
c     IF (JTLMOD .NE. 3) GO TO 60
  670 continue
      WRITE(IPRT,70)
   70 FORMAT(1H ,'PLOT DATA? 1=YES, 0=NO')
      iplt = -1
      READ(5,*,END=670,err=670) IPLT
      if (iplt .eq. -1) go to 670
      IF (IPLT .EQ. 1) GO TO 71
      IF (IPLT .EQ. 0) GO TO 60
      GO TO 670
   71 CONTINUE
      call ubell
      call clrtek
C
C START PLOT
C
C--------
C-------- THE PLOTTING CALLS NOW HAVE VARIABLE DIMENSIONS AND
C-------- ARE DETERMINED BY THE DATA STATEMENT DEFINING THE
C-------- DESIRED OVERALL SIZE.  CURRENTLY W=11.0 INCHES AND
C-------- H=8.5 INCHES.  ALL THE MULTIPLICITIVE CONSTANTS IN THE
C-------- PLOTTING CALLS ARE DETERMINED USING A DEFAULT SIZE OF
C-------- W=17.5 INCHES AND H=11.0 INCHES.
C--------
 1299 CONTINUE
C
C SELECT CURVES TO PLOT
C
 1298 continue
      WRITE (6,1300)
 1300 FORMAT (1H ,'PLOTTING OPTIONS ARE:')
      WRITE (6,1301)
 1301 FORMAT (1H ,'  IOPT=1 ==> PLOT ALL MODES USING A AND D CUPS')
      WRITE (6,1302)
 1302 FORMAT (1H ,'  IOPT=2 ==> DO NOT PLOT M-MODE     ')
      WRITE (6,1303)
 1303 FORMAT (1H ,'  IOPT=3 ==> DO NOT PLOT L-MODE     ')
      WRITE (6,1304)
 1304 FORMAT (1H ,'  IOPT=4 ==> PLOT E1, E2, AND L D-CUP')
      WRITE (6,1305)
 1305 FORMAT (1H ,'  IOPT=5 ==> PLOT E1, E2, AND M D-CUP')
      WRITE (6,1306)
 1306 FORMAT (1H ,'  IOPT=6 ==> LEAVE THIS SPECTRAL SET')
      iopt= -1
      READ (5,*,END=1298,err=1298) IOPT
      if (iopt .eq. -1) go to 1298
      IF (IOPT .EQ. 6) GO TO 60
      IF (IOPT .GT. 6) GO TO 1298
c
c Option for non DC return cups, i.e., normal A and D slots
      WRITE (6,1307)
 1307 FORMAT (1H ,'PLOT A AND D PLASMA DATA? 1=YES, 0=NO')
      iopt2= -1
      READ (5,*,END=1298,err=1298) IOPT2
      if (iopt2 .eq. -1) go to 1298
      CALL UBELL
      CALL UPAUSE
      CALL CLRTEK
C
C DO NEXT PLOT
C
      CALL nupage2(W,H)
      CALL SETXAX6(0.,1.,0,.8286*W,1,0)
      CALL SETYAX6(0.,1.,0,.9091*H,1,0)
      CALL LABEL6(1,' ',1,' ',22,'VOYAGER DC RETURN DATA')
      CALL SETAFF3(0.,.0029*W,.0045*H)
      CALL SETXAX6(0.,1.,0,.8229*W,1,0)
      CALL SETYAX6(0.,1.,0,.9*H,1,0)
      CALL LABEL6(1,' ',1,' ',1,' ')
      CALL SETYAX6(0.,1.,0,.1455*H,1,0)
      CALL LABEL6(1,' ',1,' ',1,' ')
C
C WRITE MAGNETIC FIELD AND TRAJECTORY VARIABLES ON PLOT
C
      CALL SETAFF3(0.,.0057*W,.0091*H)
      CALL SETXAX6(0.,1.,0,.8171*W,1,0)
      CALL SETYAX6(0.,1.,0,.1364*H,1,0)
      CALL LABEL6(1,' ',1,' ',1,' ')
C
C WRITE OUT INPUT TEXT STRING
C
      GO TO (405,410,415,420),NUMFOR
420   CALL LABSYM(.1229*W,.1073*H,.5417*W,'NEPTUNE MAGNETOSPHERE',0.,21)
      GO TO 102
415   CALL LABSYM(.1229*W,.1073*H,.5417*W,'URANUS MAGNETOSPHERE',0.,20)
      GO TO 102
410   CALL LABSYM(.1229*W,.1073*H,.5417*W,'SATURN MAGNETOSPHERE',0.,20)
      GO TO 102
405   CALL LABSYM(.1229*W,.1073*H,.5417*W,'JUPITER MAGNETOSPHERE',0.,21)
 102  CONTINUE
C
C WRITE OUT SPACECRAFT IDENTIFICATION
C
      XS=0.0286*W
      XT=0.4418*W
      IF (V0 .EQ. 453.)
     *CALL LABSYM(.1229*W,.0591*H,.5417*W,'VOYAGER 1',0.,9)
      IF (V0 .EQ. 372.)
     *CALL LABSYM(.1229*W,.0591*H,.5417*W,'VOYAGER 2',0.,9)
C     CALL SYMBOL(XS,.0591*H,HT,'VOYAGER ',0.,8)
C     CALL SYMCON(' - VOYAGER ',11)
C     IF (V0 .EQ. 453.) CALL SYMCON('1',1)
C     IF (V0 .EQ. 372.) CALL SYMCON('2',1)
C
C WRITE OUT TIMES OF SPECTRA
C
      CALL SYMBOL(XS,.0364*H,HT,'L -MODE TIME ',0.,13)
      CALL SYMCON(TIML,20)
      CALL SYMBOL(XT,.0364*H,HT,'M -MODE TIME ',0.,13)
      CALL SYMCON(TIMM,20)
      CALL SYMBOL(XS,.0136*H,HT,'E1-MODE TIME ',0.,13)
      CALL SYMCON(TIME1,20)
      CALL SYMBOL(XT,.0136*H,HT,'E2-MODE TIME ',0.,13)
      CALL SYMCON(TIME2,20)
C     CALL SYMBOL(XS,.0364*H,HT,TIMESR,0.,20)
      CALL SETAFF0
C PLOT HISTOGRAM OF DC RETURN CURRENT VERSUS DATA NUMBER
C RETURN CURRENT VALUES ARE STORED IN LOOKUP TABLE IN PLCONS
C
C RLM 4/2/87
C
C
C NEGATIVE DC RETURN CURRENTS:
C        DN=0   --> -1.00E 05 FA
C        DN=127 --> -1.00E 08 FA
C
C POSITIVE DC RETURN CURRENTS:
C        DN=128 --> +7.50E 04 FA
C        DN=255 --> +1.00E 08 FA
C
C IPLOT=1 REFERS TO BOTTOM PANNEL (-IDC), IPLOT=2 TO TOP (+IDC)
C
      YOFF(1)=0.2442*H
      YIN(1)=.2579*H
      YIN(2)=.3439*H
      YOFF(2)=YOFF(1)+YIN(1)
      CALL SETPLT1(0)
      DO 2500 IPLOT=1,2
      CALL SETAFF3(0.,0.1155*W,YOFF(IPLOT))
      IF (IPLOT .EQ. 1) CALL SETXAX9 (0.,272.,0,.6330*W,68,17,-1,-1,1)
C
C OMIT TIC MARKS ACROSS BOTTOM OF TOP PANEL
C
      IF (IPLOT .EQ. 2) CALL SETXAX9 (0.,272.,0,.6330*W,68,17,-1,1,-1)
      CALL SETYAX7 (YB(IPLOT),YT(IPLOT),0,YIN(IPLOT),NT(IPLOT),
     *NLT(IPLOT),-1)
C     CALL SETYAX (YB(IPLOT),YT(IPLOT),0,.6189*H,64,16,-1)
      IF (IPLOT .EQ. 1) CALL LABEL6(26,'GENERALIZED CHANNEL NUMBER',
     *19,'- LOG10 (- CURRENT)',1,' ')
      IF (IPLOT .EQ. 2) CALL LABEL6(1,' ',
     *19,'+ LOG10 (+ CURRENT)',1,' ')
c
c Put on zero current line
c
      if (iplot .eq. 1) 
     +CALL HISTRA5(CHAN(1),CHAN(2),CURNULL,CURNULL,272)      
C
C PUT DATA IN PANEL
C
C
C SETUP DIFFERENT MODES
C
      DO 950 I=1,272
      CURPLT(I)=PRESET
  950 CONTINUE
      IF (IOPT .EQ. 2) GO TO 6010
      IF (IOPT .EQ. 4) GO TO 6050
C
C M-MODE, A-CUP
C
      IF (IOPT .EQ. 5) GO TO 6030
      DO 2951 I=1,144
 2951 CURPLT(I)=PRESET
      DO 951 I=145,272
      IF (CIMA(I) .GT. 0.) CURPLT(I)=ALOG10(CIMA(I))
      IF (CIMA(I) .LT. 0.) CURPLT(I)=-ALOG10(-CIMA(I))
  951 CONTINUE
      CALL HISTRA5(CHAN(1),CHAN(2),CURPLT,CURPLT,272)
      if (iopt2 .eq. 0) go to 6030
c
c M-mode, A cup plasma data
c
      DO 7951 I=1,144
 7951 CURPLT(I)=PRESET
      DO 751 I=145,272
      IF (cipma(I) .GT. 0.) CURPLT(I)=ALOG10(cipma(I))
  751 CONTINUE
      CALL HISTRA5(CHAN(1),CHAN(2),CURPLT,CURPLT,272)
 6030 CONTINUE
C
C M-MODE, D-CUP
C
      DO 2952 I=1,144
 2952 CURPLT(I)=PRESET
      DO 952 I=145,272
      IF (CIMD(I) .GT. 0.) CURPLT(I)=ALOG10(CIMD(I))
      IF (CIMD(I) .LT. 0.) CURPLT(I)=-ALOG10(-CIMD(I))
  952 CONTINUE
      CALL HISTRA5(CHAN(1),CHAN(2),CURPLT,CURPLT,272)
      if (iopt2 .eq. 0) go to 6031
c     
c M-mode, D cup plasma data 
c 
      DO 7952 I=1,144 
 7952 CURPLT(I)=PRESET 
      DO 752 I=145,272 
      IF (cipmd(I) .GT. 0.) CURPLT(I)=ALOG10(cipmd(I)) 
  752 CONTINUE 
      CALL HISTRA5(CHAN(1),CHAN(2),CURPLT,CURPLT,272)
 6031 continue
 6010 CONTINUE
      IF (IOPT .EQ. 3) GO TO 6020
      IF (IOPT .EQ. 5) GO TO 6040
C
C L-MODE, A-CUP
C
      DO 2953 I=1,144
 2953 CURPLT(I)=PRESET
      DO 953 I=145,272
      IF (CILA(I) .GT. 0.) CURPLT(I)=ALOG10(CILA(I))
      IF (CILA(I) .LT. 0.) CURPLT(I)=-ALOG10(-CILA(I))
  953 CONTINUE
      CALL HISTRA5(CHAN(1),CHAN(2),CURPLT,CURPLT,272)
c     if (iopt2 .eq. 0) go to 6050
c
c L-mode, A cup plasma data 
c 
      DO 7953 I=1,144 
 7953 CURPLT(I)=PRESET 
      DO 753 I=145,272 
      IF (cipla(I) .GT. 0.) CURPLT(I)=ALOG10(cipla(I)) 
  753 CONTINUE 
      CALL HISTRA5(CHAN(1),CHAN(2),CURPLT,CURPLT,272)
 6050 CONTINUE
C
C L-MODE, D-CUP
C
      DO 2954 I=1,144
 2954 CURPLT(I)=PRESET
      DO 954 I=145,272
      IF (CILD(I) .GT. 0.) CURPLT(I)=ALOG10(CILD(I))
      IF (CILD(I) .LT. 0.) CURPLT(I)=-ALOG10(-CILD(I))
  954 CONTINUE
      CALL HISTRA5(CHAN(1),CHAN(2),CURPLT,CURPLT,272)
      if (iopt2 .eq. 0) go to 6020 
c 
c L-mode, D cup plasma data  
c  
      DO 7954 I=1,144  
 7954 CURPLT(I)=PRESET  
      DO 754 I=145,272 
      IF (cipld(I) .GT. 0.) CURPLT(I)=ALOG10(cipld(I))  
  754 CONTINUE   
      CALL HISTRA5(CHAN(1),CHAN(2),CURPLT,CURPLT,272)
 6020 CONTINUE
 6040 CONTINUE
C
C E1 MODE
C
      DO 2955 I=1,96
 2955 CURPLT(I)=PRESET
      DO 3955 I=129,272
 3955 CURPLT(I)=PRESET
      DO 955 I=97,128
      IF (CIE1(I) .GT. 0.) CURPLT(I)=ALOG10(CIE1(I))
      IF (CIE1(I) .LT. 0.) CURPLT(I)=-ALOG10(-CIE1(I))
  955 CONTINUE
      CALL HISTRA5(CHAN(1),CHAN(2),CURPLT,CURPLT,272)
C
C E2 MODE
C
      DO 2956 I=129,272
 2956 CURPLT(I)=0.0
      DO 956 I=1,128
      IF (CIE2(I) .GT. 0.) CURPLT(I)=ALOG10(CIE2(I))
      IF (CIE2(I) .LT. 0.) CURPLT(I)=-ALOG10(-CIE2(I))
  956 CONTINUE
      CALL HISTRA5(CHAN(1),CHAN(2),CURPLT,CURPLT,272)
C
C LOOP FOR NEXT PANEL
C
      CALL SETAFF0
 2500 CONTINUE
 100  CONTINUE
      CALL UBELL
      CALL UPAUSE
   60 continue
      return
      end
