Script started on Sun 18 Jun 2023 10:16:08 AM ED jwb@faraday.mit.edu[40]$ mjs.nep Enter the spacecraft id (1 - Voyager 1; 2 - Voyager 2): 2 INPUT IPLNT(0,1,2,3,4 CRU JUP SAT URA NEPT) 4 ======================================== Encounter Mode (Spectral tape) ======================================== Trajectory file selection: 0 ==> Do not mount trajectory file 1 ==> Use short encounter file (via PHASE2) 1 CUP RESPONSE AT NORMAL INCIDENCE 66.10 56.24 *** NEPTUNE DATA DISPLAY *** SEDR DATA FILE COVERS: SPECTRAL DATA FILE STARTS AT: V2 - 0 0 0 0 TO 0 0 0 0 V2 - 1989 233 1955 Do joint ion/electron analysis? 2=M, E1, E2; 1=L, E1, E2; 0=NO 0 Select Data Mode: 1 = Plasma, 2 = DC Return, 3 = MODCAL and CURCAL, 4 = All 1 Integrate Plasma Data? (Analysis Skipped) 2=YES for DC return spectra 1=YES for plasma spectra 0=NO 0 Select Spectral Type: 0 = all, 1 = ions only, 2 = electrons only 3 = L only, 4 = M only, 5 = E1 only, 6 = E2 only, 7 = LS, E1S, E2S only 3 INPUT START TIME: IYR, IDAY, IHR, IMIN, ISEC, IMSEC 1989 237 0 18 0 0 Input number of spectra to average (0= no ave.) 0 CAP 0.15 GAIN 2.00 CLOCK 0.93 V0 THRESHOLD 372.00 3.00 TIME OF CURRENT SPECTRUM IS 1989 237 0 18 3 167 CURRENT SPECTRUM IS AN L-MODE MODULATOR ON, PLASMA, NORMAL SUPPRESSOR PLOT JUST DATA? (NO FIT YET) 1=YES, 0=NO 1 THRESHOLD IS 3.0549E+00 FEMTOAMPS. SATURATION IS 2.9470E+04 FEMTOAMPS. MINIMUM AND MAXIMUM CURRENTS (IN FEMTOAMPS) ARE: 3.055E+00 1.718E+03 IN CUP 1 3.055E+00 1.542E+02 IN CUP 2 3.055E+00 2.057E+02 IN CUP 3 3.055E+00 5.241E+02 IN CUP 4 WRITE OUT ALL CURRENTS? 1=YES, 0=NO 0 THE SCALE STARTS AT 1.00E-01 FEMTOAMPS AND GOES UP 6 DECADES CHANGE CURRENT SCALE FROM CURRENT VALUE? 1=YES 0=NO 1 YB (MUST BE A POWER OF 10),IDEC (NUMBER OF DECADES) 1,4 gnuplot -e "t= 1.00000000 ; u= 4 " gnutest_L Hit return to continue CONTINUE WITH ANALYSIS? 1 for YES, 0 for NO 1 DO NONLINEAR LEAST SQUARES ANALYSIS WITH CURRENT SPECTRA? INPUT NUMBER of ITERATIONS. A negative number uses unit 15 as a remote input file 1 SELECT FITTING OPTION: if negative calculate current 0 ==> DO NOT DO FIT 1 ==> FIT USING PMODEL 3 ==> FIT USING XJC (UNITY RESPONSE) 4 ==> FIT USING ABSO (L OR M MODES - LABCUR,LDCUR) 5 ==> FIT USING ABSOM (M-MODE ONLY - ABCCUR,DCUR) 6 ==> FIT USING ABSO (BIMAXWELLIAN VERSION) 7 ==> FIT USING COLD BEAM (CUPINT,DCPINT) 9 ==> FIT USING VERY COLD BEAM (CUPEXP) GT 10 ==> TERMINATE EXECUTION 4 Correct L mode currents for noise? 1=Yes, 0=No 0 1 ** PARAMETERS FOR USE IN ANALYSIS ** INPUT NUMBER OF COMPONENTS TO FIT TO SPECTRA 2 DO YOU WISH TO HAVE DENSITY AS A FIT PARAMETER? (T OR F) t INDICATE WHICH DENSITIES TO FIT (T OR F FOR EACH OF THE 2 SPECIES) t,t Use CYL coordinates ==> 1 Use S/C coordinates ==> 2 Use RTN coordinates ==> 3 1 INPUT LOGICAL VARIABLES (T OR F ) TO SELECT FIT PARAMETERS FIT VR, VPHI, VZ FOR COMPONENT 1 ? f,t,f FIT THERMAL SPEED FOR THIS COMPONENT ? t INPUT MASS AND CHARGE STATE ( INTEGERS ) OF COMPONENT 1 1,1 INPUT LOGICAL VARIABLES (T OR F ) TO SELECT FIT PARAMETERS FIT VR, VPHI, VZ FOR COMPONENT 2 ? f,f,f FIT THERMAL SPEED FOR THIS COMPONENT ? t INPUT MASS AND CHARGE STATE ( INTEGERS ) OF COMPONENT 2 14,1 USE ISOTROPIC MAXWELLIANS IN FIT ? t MARQUARDTS PARAMETER (FLAM) IS SET TO 0.1000E+00 THE PARTIAL DERIVATIVE PARAMETER (ALAM) IS SET TO 0.1000E-02 OVERRIDE THESE VALUES ? 1=YES, 0=NO 0 NCOMP CHARGE MASS FIT N FIT VR FIT VPHI FIT VZ FIT W 1 1 1 T F T F T 2 1 14 T F F F T FLAM = 0.100 ALAM = 0.001 ISOTROPIC MAXWELLIAN T SAME TEMPERATURE T CHANGE FIT OPTIONS? 1=YES, 0=NO 0 HOW MANY CONTIGUOUS SETS OF CHANNELS? in cup 1 0 HOW MANY CONTIGUOUS SETS OF CHANNELS? in cup 2 1 INPUT LOWER AND UPPER CHANNELS FOR SET 1 1 1 HOW MANY CONTIGUOUS SETS OF CHANNELS? in cup 3 1 INPUT LOWER AND UPPER CHANNELS FOR SET 1 1 1 HOW MANY CONTIGUOUS SETS OF CHANNELS? in cup 4 1 INPUT LOWER AND UPPER CHANNELS FOR SET 1 1 9 VELOCITY IS INITIALIZED TO THAT OF RIGID COROTATION THERMAL SPEEDS INITIALIZED ASSUMING MACH 3 FLOW DENSITIES ESTIMATED FROM DATA IN CUP 4, DIVIDED BY "NCOMP" NCOMP VR VPHI VZ W DEN 1 0.000 26.291 0.000 8.764 0.000 2 0.000 26.291 0.000 8.764 0.000 HOW MANY SPECIES DO YOU WISH TO MODIFY FIT PARAMETERS OF? 0=NONE 9=ALL 9 INPUT LOGICAL VARIABLES (T OR F) FOR PARAMETERS YOU WISH CHANGED CHANGE VR,VPHI,VZ,W,DEN FOR COMPONENT 1 t,t,t,t,t INPUT NEW VALUES OF VR,VPHI,VZ,WPAR,DEN FOR COMPONENT 1 0.000 23.745 0.000 40.000 0.05 INPUT LOGICAL VARIABLES (T OR F) FOR PARAMETERS YOU WISH CHANGED CHANGE VR,VPHI,VZ,W,DEN FOR COMPONENT 2 t,t,t,t,t INPUT NEW VALUES OF VR,VPHI,VZ,WPAR,DEN FOR COMPONENT 2 0.000 23.745 0.000 30.000 0.05 BELOW ARE THE CURRENT VALUES OF THE FIT PARAMETERS NCOMP VR VPHI VZ W DEN 1 0.000 23.745 0.000 40.000 0.050 2 0.000 23.745 0.000 30.000 0.050 DO YOU WISH TO MAKE ANY FURTHER CHANGES? 1=YES 0=NO 0 WANT THE BEST FIT DIRECTLY? 1=YES, 0=NO 1 REINITIALIZE FIT MATRICES FROM PREVIOUS SESSION? 1=YES, 0=NO 0 FIRST CALL TO XFNCDV TO INITIALIZE FITTING RUN CHISQR USING FIRST GUESS NO ITERATIONS: 2.5 CONTINUE? 1=YES, 0=NO, 2=RESOLUTION ANALYSIS PLOT ITERATION 0? (PLOT 0 IS NO ITERATION: USES INITIAL GUESS AND MODEL CURRENTS FROM THAT GUESS) 1=YES, 0=NO PARAMETERS BEFORE/AFTER ITERATION 1 AND % CHANGE 0.05 0.05 23.75 40.00 30.00 0.06 0.04 24.65 39.41 32.70 25.21 -23.53 3.82 -1.46 8.99 CONTINUE TO NEXT ITERATION 1=YES; 0=NO ANOTHER CALL TO XFNCDV TO SET UP ITERATION 2 *** NOTE DECREASE IN CHI SQUARE IN ITERATION 1 **** IN ITERATION 1 CHI SQUARE DECREASED FROM 2.5 TO 0.2, PERCENT DECREASE: -91.59 DELTA IS 0.92 GOAL IS TO GET BELOW 0.10 VALUE OF FLAMDA IS 0.01000000 CONTINUING ITERATION NUMBER 2 AFTER TOTAL NUMBER OF CALLS TO XFNCDV OF: 2 PREVIOUS CHI SQUARE = 0.2 CONTINUE? 1=YES, 0=NO, 2=RESOLUTION ANALYSIS PLOT ITERATION 1? 1=YES, 0=NO PARAMETERS BEFORE/AFTER ITERATION 2 AND % CHANGE 0.06 0.04 24.65 39.41 32.70 0.07 0.04 23.18 39.35 34.98 6.95 5.97 -5.97 -0.16 6.98 CONTINUE TO NEXT ITERATION 1=YES; 0=NO ANOTHER CALL TO XFNCDV TO SET UP ITERATION 3 *** NOTE DECREASE IN CHI SQUARE IN ITERATION 2 **** IN ITERATION 2 CHI SQUARE DECREASED FROM 0.2 TO 0.2, PERCENT DECREASE: -24.67 DELTA IS 0.25 GOAL IS TO GET BELOW 0.10 VALUE OF FLAMDA IS 0.00100000 CONTINUING ITERATION NUMBER 3 AFTER TOTAL NUMBER OF CALLS TO XFNCDV OF: 3 PREVIOUS CHI SQUARE = 0.2 CONTINUE? 1=YES, 0=NO, 2=RESOLUTION ANALYSIS PLOT ITERATION 2? 1=YES, 0=NO PARAMETERS BEFORE/AFTER ITERATION 3 AND % CHANGE 0.07 0.04 23.18 39.35 34.98 0.07 0.04 22.55 39.34 35.38 2.91 2.94 -2.72 -0.03 1.13 CONTINUE TO NEXT ITERATION 1=YES; 0=NO ANOTHER CALL TO XFNCDV TO SET UP ITERATION 4 *** NOTE DECREASE IN CHI SQUARE IN ITERATION 3 **** IN ITERATION 3 CHI SQUARE DECREASED FROM 0.2 TO 0.2, PERCENT DECREASE: -1.56 DELTA IS 0.02 GOAL IS TO GET BELOW 0.10 VALUE OF FLAMDA IS 0.00010000 CONTINUING ITERATION NUMBER 4 AFTER TOTAL NUMBER OF CALLS TO XFNCDV OF: 4 PREVIOUS CHI SQUARE = 0.2 CONTINUE? 1=YES, 0=NO, 2=RESOLUTION ANALYSIS FIT DONE AND WE ARE OUT OF XMJSFT IQUAL AND ICALL ARE 0 3 PLOT FINAL RESULTS: THE SCALE STARTS AT 1.00E+00 FEMTOAMPS AND GOES UP 4 DECADES CHANGE CURRENT SCALE FROM CURRENT VALUE? 1=YES 0=NO 0 gnuplot -e "t= 1.00000000 ; u= 4 " gnutest_L Hit return to continue Write output to file 29? 1=Yes, 0=No. 1 Write numerical output to file 28? 1=Yes, 0=No. 1 *** THIS IS A BEST FIT *** FIT COMPLETED AT 10:21:48 ON Jun 18 3 FIT OF SPECTRA AT TIME 1989 237 0 18 3 167 CUP CHANNELS USED IN FIT BY ABSO A-CUP: *** NO FIT PERFORMED *** B-CUP: CHANNELS 1 - 1 C-CUP: CHANNELS 1 - 1 D-CUP: CHANNELS 1 - 9 CHI SQUARE = 1.56639E-01 CURRENTS WERE GENERATED USING ABSO SINGLE PRECISION CODE WAS USED MASS NQ DEN XDEN VR XVR VPHI XVPHI VZ XVZ W XW 1 1 0.0689 0.0073 0.0000 0.0000 22.5494 2.7496 0.0000 0.0000 39.3401 0.8552 14 1 0.0417 0.0056 0.0000 0.0000 22.5494 2.7496 0.0000 0.0000 35.3759 1.9787 PARTICLE VELOCITIES IN S/C COORDINATES (KM/SEC) NCOMP VX VY VZ 1 -24.03 -12.06 -12.28 2 -24.03 -12.06 -12.28 PARTICLE VELOCITIES IN RTN COORDINATES (KM/SEC) *** CORRECTED FOR S/C MOTION *** NCOMP VR VT VN 1 4.67 -21.92 2.52 2 4.67 -21.92 2.52 PROJECTION OF FITTED VELOCITIES ALONG CUP NORMALS (KM/SEC) NCOMP VA VB VC VD 1 -20.72 -6.49 -7.42 25.36 2 -20.72 -6.49 -7.42 25.36 PROJECTION OF Magnetic Field ALONG CUP NORMALS (Gamma) BA BB BC BD |B| 0.00 -0.00 -0.00 -0.00 0.00 DO NONLINEAR LEAST SQUARES ANALYSIS WITH CURRENT SPECTRA? INPUT NUMBER of ITERATIONS. A negative number uses unit 15 as a remote input file ^C jwb@faraday.mit.edu[41]$ exit exit Script done on Sun 18 Jun 2023 10:21:52 AM ED