Script started on Sat 17 Jun 2023 09:41:55 AM EDT jwb@faraday.mit.edu[33]$ mjs.sat Enter the spacecraft id (1 - Voyager 1; 2 - Voyager 2): 2 INPUT IPLNT(0,1,2,3,4 CRU JUP SAT URA NEPT) 2 ======================================== Encounter Mode (Spectral tape) ======================================== Trajectory file selection: 0 ==> Do not mount trajectory file 1 ==> Use short encounter file (via PHASE2) 1 CUP RESPONSE AT NORMAL INCIDENCE 66.10 56.24 *** SATURN DATA DISPLAY *** Do joint ion/electron analysis? 2=M, E1, E2; 1=L, E1, E2; 0=NO 0 Select Data Mode: 1 = Plasma, 2 = DC Return, 3 = MODCAL and CURCAL, 4 = All 1 Integrate Plasma Data? (Analysis Skipped) 2=YES for DC return spectra 1=YES for plasma spectra 0=NO 0 Select Spectral Type: 0 = all, 1 = ions only, 2 = electrons only 3 = L only, 4 = M only, 5 = E1 only, 6 = E2 only, 7 = LS, E1S, E2S only 3 INPUT START TIME: IYR, IDAY, IHR, IMIN, ISEC, IMSEC 1981 237 12 9 11 0 Input number of spectra to average (0= no ave.) 0 CAP 0.15 GAIN 2.00 CLOCK 0.21 V0 THRESHOLD fact1 fact2 JCLK 372.00 13.29 13.29 13.29 2 TIME OF CURRENT SPECTRUM IS 1981 237 12 9 11 986 CURRENT SPECTRUM IS AN L-MODE Distance to Titan center =681751.25 = altitude of 679176.25 MODULATOR ON, PLASMA, NORMAL SUPPRESSOR PLOT JUST DATA? (NO FIT YET) 1=YES, 0=NO 1 THRESHOLD IS 1.3529E+01 FEMTOAMPS. SATURATION IS 1.3051E+05 FEMTOAMPS. MINIMUM AND MAXIMUM CURRENTS (IN FEMTOAMPS) ARE: 1.353E+01 1.507E+03 IN CUP 1 1.353E+01 3.705E+03 IN CUP 2 1.353E+01 6.131E+02 IN CUP 3 1.214E+02 2.010E+03 IN CUP 4 WRITE OUT ALL CURRENTS? 1=YES, 0=NO 0 THE SCALE STARTS AT 1.00E-01 FEMTOAMPS AND GOES UP 6 DECADES CHANGE CURRENT SCALE FROM CURRENT VALUE? 1=YES 0=NO 10,3 CHANGE CURRENT SCALE FROM CURRENT VALUE? 1=YES 0=NO 1 YB (MUST BE A POWER OF 10),IDEC (NUMBER OF DECADES) 10,3 rm: cannot remove ‘data.txt’: No such file or directory gnuplot -e "t= 10.0000000 ; u= 3 " gnutest_L Hit return to continue CONTINUE WITH ANALYSIS? 1 for YES, 0 for NO 1 DO NONLINEAR LEAST SQUARES ANALYSIS WITH CURRENT SPECTRA? INPUT NUMBER of ITERATIONS. A negative number uses unit 15 as a remote input file 1 SELECT FITTING OPTION: if negative calculate current 0 ==> DO NOT DO FIT 1 ==> FIT USING PMODEL 3 ==> FIT USING XJC (UNITY RESPONSE) 4 ==> FIT USING ABSO (L OR M MODES - LABCUR,LDCUR) 5 ==> FIT USING ABSOM (M-MODE ONLY - ABCCUR,DCUR) 6 ==> FIT USING ABSO (BIMAXWELLIAN VERSION) 7 ==> FIT USING COLD BEAM (CUPINT,DCPINT) 9 ==> FIT USING VERY COLD BEAM (CUPEXP) GT 10 ==> TERMINATE EXECUTION 4 Correct L mode currents for noise? 1=Yes, 0=No 0 1 ** PARAMETERS FOR USE IN ANALYSIS ** INPUT NUMBER OF COMPONENTS TO FIT TO SPECTRA 2 DO YOU WISH TO HAVE DENSITY AS A FIT PARAMETER? (T OR F) t INDICATE WHICH DENSITIES TO FIT (T OR F FOR EACH OF THE 2 SPECIES) t,t Use CYL coordinates ==> 1 Use S/C coordinates ==> 2 Use RTN coordinates ==> 3 1 INPUT LOGICAL VARIABLES (T OR F ) TO SELECT FIT PARAMETERS FIT VR, VPHI, VZ FOR COMPONENT 1 ? t,t,t FIT THERMAL SPEED FOR THIS COMPONENT ? t INPUT MASS AND CHARGE STATE ( INTEGERS ) OF COMPONENT 1 1,1 INPUT LOGICAL VARIABLES (T OR F ) TO SELECT FIT PARAMETERS FIT VR, VPHI, VZ FOR COMPONENT 2 ? f,f,f FIT THERMAL SPEED FOR THIS COMPONENT ? t INPUT MASS AND CHARGE STATE ( INTEGERS ) OF COMPONENT 2 14,1 USE ISOTROPIC MAXWELLIANS IN FIT ? t MARQUARDTS PARAMETER (FLAM) IS SET TO 0.1000E+00 THE PARTIAL DERIVATIVE PARAMETER (ALAM) IS SET TO 0.1000E-02 OVERRIDE THESE VALUES ? 1=YES, 0=NO 0 NCOMP CHARGE MASS FIT N FIT VR FIT VPHI FIT VZ FIT W 1 1 1 T T T T T 2 1 14 T F F F T FLAM = 0.100 ALAM = 0.001 ISOTROPIC MAXWELLIAN T SAME TEMPERATURE T CHANGE FIT OPTIONS? 1=YES, 0=NO 0 HOW MANY CONTIGUOUS SETS OF CHANNELS? in cup 1 0 HOW MANY CONTIGUOUS SETS OF CHANNELS? in cup 2 1 INPUT LOWER AND UPPER CHANNELS FOR SET 1 1 3 HOW MANY CONTIGUOUS SETS OF CHANNELS? in cup 3 1 INPUT LOWER AND UPPER CHANNELS FOR SET 1 1 3 HOW MANY CONTIGUOUS SETS OF CHANNELS? in cup 4 1 INPUT LOWER AND UPPER CHANNELS FOR SET 1 1 10 VELOCITY IS INITIALIZED TO THAT OF RIGID COROTATION THERMAL SPEEDS INITIALIZED ASSUMING MACH 3 FLOW DENSITIES ESTIMATED FROM DATA IN CUP 4, DIVIDED BY "NCOMP" NCOMP VR VPHI VZ W DEN 1 0.000 134.831 0.000 44.944 0.000 2 0.000 134.831 0.000 44.944 0.000 HOW MANY SPECIES DO YOU WISH TO MODIFY FIT PARAMETERS OF? 0=NONE 9=ALL 9 INPUT LOGICAL VARIABLES (T OR F) FOR PARAMETERS YOU WISH CHANGED CHANGE VR,VPHI,VZ,W,DEN FOR COMPONENT 1 t,t,t,t,t INPUT NEW VALUES OF VR,VPHI,VZ,WPAR,DEN FOR COMPONENT 1 0.000 120.000 0.000 60.000 0.16 INPUT LOGICAL VARIABLES (T OR F) FOR PARAMETERS YOU WISH CHANGED CHANGE VR,VPHI,VZ,W,DEN FOR COMPONENT 2 t,t,t,t,t INPUT NEW VALUES OF VR,VPHI,VZ,WPAR,DEN FOR COMPONENT 2 0.000 134.783 0.000 20.000 0.10 BELOW ARE THE CURRENT VALUES OF THE FIT PARAMETERS NCOMP VR VPHI VZ W DEN 1 0.000 120.000 0.000 60.000 0.160 2 0.000 134.783 0.000 20.000 0.100 DO YOU WISH TO MAKE ANY FURTHER CHANGES? 1=YES 0=NO 0 WANT THE BEST FIT DIRECTLY? 1=YES, 0=NO 0 REINITIALIZE FIT MATRICES FROM PREVIOUS SESSION? 1=YES, 0=NO 0 FIRST CALL TO XFNCDV TO INITIALIZE FITTING RUN CHISQR USING FIRST GUESS NO ITERATIONS: 365.5 CONTINUE? 1=YES, 0=NO, 2=RESOLUTION ANALYSIS 1 PLOT ITERATION 0? (PLOT 0 IS NO ITERATION: USES INITIAL GUESS AND MODEL CURRENTS FROM THAT GUESS) 1=YES, 0=NO 1 THE SCALE STARTS AT 1.00E+01 FEMTOAMPS AND GOES UP 3 DECADES CHANGE CURRENT SCALE FROM CURRENT VALUE? 1=YES 0=NO0 gnuplot -e "t= 10.0000000 ; u= 3 " gnutest_L Hit return to continue AT 6677 0 1 PARAMETERS BEFORE/AFTER ITERATION 1 AND % CHANGE 0.16 0.10 0.00 120.00 0.00 60.00 20.00 0.12 0.05 -13.30 119.22 33.39 63.45 25.82 -26.32 -49.13 -Infinity -0.65 Infinity 5.74 29.10 CONTINUE TO NEXT ITERATION 1=YES; 0=NO 1 ANOTHER CALL TO XFNCDV TO SET UP ITERATION 2 *** NOTE DECREASE IN CHI SQUARE IN ITERATION 1 **** IN ITERATION 1 CHI SQUARE DECREASED FROM 365.5 TO 29.8, PERCENT DECREASE: -91.83 DELTA IS 0.92 GOAL IS TO GET BELOW 0.10 VALUE OF FLAMDA IS 0.01000000 CONTINUING ITERATION NUMBER 2 AFTER TOTAL NUMBER OF CALLS TO XFNCDV OF: 2 PREVIOUS CHI SQUARE = 29.8 CONTINUE? 1=YES, 0=NO, 2=RESOLUTION ANALYSIS 1 PLOT ITERATION 1? 1=YES, 0=NO 1 THE SCALE STARTS AT 1.00E+01 FEMTOAMPS AND GOES UP 3 DECADES CHANGE CURRENT SCALE FROM CURRENT VALUE? 1=YES 0=NO0 gnuplot -e "t= 10.0000000 ; u= 3 " gnutest_L Hit return to continue AT 6677 1 2 PARAMETERS BEFORE/AFTER ITERATION 2 AND % CHANGE 0.12 0.05 -13.30 119.22 33.39 63.45 25.82 0.14 0.08 -10.42 104.36 40.76 67.08 49.83 16.79 66.70 21.60 -12.47 22.08 5.72 92.99 CONTINUE TO NEXT ITERATION 1=YES; 0=NO 1 ANOTHER CALL TO XFNCDV TO SET UP ITERATION 3 *** NOTE DECREASE IN CHI SQUARE IN ITERATION 2 **** IN ITERATION 2 CHI SQUARE DECREASED FROM 29.8 TO 12.7, PERCENT DECREASE: -57.40 DELTA IS 0.57 GOAL IS TO GET BELOW 0.10 VALUE OF FLAMDA IS 0.00100000 CONTINUING ITERATION NUMBER 3 AFTER TOTAL NUMBER OF CALLS TO XFNCDV OF: 3 PREVIOUS CHI SQUARE = 12.7 CONTINUE? 1=YES, 0=NO, 2=RESOLUTION ANALYSIS 1 PLOT ITERATION 2? 1=YES, 0=NO 1 THE SCALE STARTS AT 1.00E+01 FEMTOAMPS AND GOES UP 3 DECADES CHANGE CURRENT SCALE FROM CURRENT VALUE? 1=YES 0=NO0 gnuplot -e "t= 10.0000000 ; u= 3 " gnutest_L Hit return to continue AT 6677 2 3 PARAMETERS BEFORE/AFTER ITERATION 3 AND % CHANGE 0.14 0.08 -10.42 104.36 40.76 67.08 49.83 0.18 0.04 -3.64 91.59 51.51 72.60 -3.84 32.24 -57.61 65.05 -12.23 26.37 8.24 -107.71 CONTINUE TO NEXT ITERATION 1=YES; 0=NO 1 ANOTHER CALL TO XFNCDV TO SET UP ITERATION 4 ** NOTE !!INCREASE!! IN CHI SQUARE IN ITERATION 3 ** IN ITERATION 3 CHI SQUARE INCREASED FROM 12.7 TO 70.0, PERCENT INCREASE: 450.71 DELTA IS 4.51 GOAL IS TO GET BELOW 0.10 VALUE OF FLAMDA IS 0.01000000 CONTINUING ITERATION NUMBER 4 AFTER TOTAL NUMBER OF CALLS TO XFNCDV OF: PREVIOUS CHI SQUARE = 70.0 CONTINUE? 1=YES, 0=NO, 2=RESOLUTION ANALYSIS 1 PLOT ITERATION 3? 1=YES, 0=NO 1 THE SCALE STARTS AT 1.00E+01 FEMTOAMPS AND GOES UP 3 DECADES CHANGE CURRENT SCALE FROM CURRENT VALUE? 1=YES 0=NO0 gnuplot -e "t= 10.0000000 ; u= 3 " gnutest_L Hit return to continue AT 6677 3 4 PARAMETERS BEFORE/AFTER ITERATION 4 AND % CHANGE 0.14 0.08 -10.42 104.36 40.76 67.08 49.83 0.17 0.07 -4.23 92.86 47.14 70.82 14.79 25.00 -22.74 59.44 -11.02 15.65 5.57 -70.31 CONTINUE TO NEXT ITERATION 1=YES; 0=NO 1 ANOTHER CALL TO XFNCDV TO SET UP ITERATION 5 *** NOTE DECREASE IN CHI SQUARE IN ITERATION 4 **** IN ITERATION 4 CHI SQUARE DECREASED FROM 70.0 TO 21.7, PERCENT DECREASE: -69.07 DELTA IS 0.69 GOAL IS TO GET BELOW 0.10 VALUE OF FLAMDA IS 0.00100000 CONTINUING ITERATION NUMBER 5 AFTER TOTAL NUMBER OF CALLS TO XFNCDV OF: 5 PREVIOUS CHI SQUARE = 21.7 CONTINUE? 1=YES, 0=NO, 2=RESOLUTION ANALYSIS 1 PLOT ITERATION 4? 1=YES, 0=NO 1 THE SCALE STARTS AT 1.00E+01 FEMTOAMPS AND GOES UP 3 DECADES CHANGE CURRENT SCALE FROM CURRENT VALUE? 1=YES 0=NO0 gnuplot -e "t= 10.0000000 ; u= 3 " gnutest_L Hit return to continue1 AT 6677 4 5 PARAMETERS BEFORE/AFTER ITERATION 5 AND % CHANGE 0.17 0.07 -4.23 92.86 47.14 70.82 14.79 0.19 0.11 -9.46 94.75 59.45 68.64 26.57 10.33 64.07 -123.70 2.04 26.11 -3.08 79.61 CONTINUE TO NEXT ITERATION 1=YES; 0=NO 1 ANOTHER CALL TO XFNCDV TO SET UP ITERATION 6 *** NOTE DECREASE IN CHI SQUARE IN ITERATION 5 **** IN ITERATION 5 CHI SQUARE DECREASED FROM 21.7 TO 5.1, PERCENT DECREASE: -76.38 DELTA IS 0.76 GOAL IS TO GET BELOW 0.10 VALUE OF FLAMDA IS 0.00010000 CONTINUING ITERATION NUMBER 6 AFTER TOTAL NUMBER OF CALLS TO XFNCDV OF: 6 PREVIOUS CHI SQUARE = 5.1 CONTINUE? 1=YES, 0=NO, 2=RESOLUTION ANALYSIS 1 PLOT ITERATION 5? 1=YES, 0=NO 1 THE SCALE STARTS AT 1.00E+01 FEMTOAMPS AND GOES UP 3 DECADES CHANGE CURRENT SCALE FROM CURRENT VALUE? 1=YES 0=NO0 gnuplot -e "t= 10.0000000 ; u= 3 " gnutest_L Hit return to continue AT 6677 5 6 PARAMETERS BEFORE/AFTER ITERATION 6 AND % CHANGE 0.19 0.11 -9.46 94.75 59.45 68.64 26.57 0.19 0.13 -9.18 95.44 59.95 68.18 32.40 0.26 16.74 2.94 0.72 0.85 -0.66 21.96 CONTINUE TO NEXT ITERATION 1=YES; 0=NO 1 ANOTHER CALL TO XFNCDV TO SET UP ITERATION 7 *** NOTE DECREASE IN CHI SQUARE IN ITERATION 6 **** IN ITERATION 6 CHI SQUARE DECREASED FROM 5.1 TO 2.6, PERCENT DECREASE: -49.47 DELTA IS 0.49 GOAL IS TO GET BELOW 0.10 VALUE OF FLAMDA IS 0.00001000 CONTINUING ITERATION NUMBER 7 AFTER TOTAL NUMBER OF CALLS TO XFNCDV OF: 7 PREVIOUS CHI SQUARE = 2.6 CONTINUE? 1=YES, 0=NO, 2=RESOLUTION ANALYSIS 1 PLOT ITERATION 6? 1=YES, 0=NO 1 THE SCALE STARTS AT 1.00E+01 FEMTOAMPS AND GOES UP 3 DECADES CHANGE CURRENT SCALE FROM CURRENT VALUE? 1=YES 0=NO0 gnuplot -e "t= 10.0000000 ; u= 3 " gnutest_L Hit return to continue AT 6677 6 7 PARAMETERS BEFORE/AFTER ITERATION 7 AND % CHANGE 0.19 0.13 -9.18 95.44 59.95 68.18 32.40 0.18 0.12 -9.78 96.50 58.06 67.69 31.81 -3.34 -4.47 -6.50 1.12 -3.15 -0.72 -1.83 CONTINUE TO NEXT ITERATION 1=YES; 0=NO 1 ANOTHER CALL TO XFNCDV TO SET UP ITERATION 8 *** NOTE DECREASE IN CHI SQUARE IN ITERATION 7 **** IN ITERATION 7 CHI SQUARE DECREASED FROM 2.6 TO 2.5, PERCENT DECREASE: -1.64 DELTA IS 0.02 GOAL IS TO GET BELOW 0.10 VALUE OF FLAMDA IS 0.00000100 CONTINUING ITERATION NUMBER 8 AFTER TOTAL NUMBER OF CALLS TO XFNCDV OF: 8 PREVIOUS CHI SQUARE = 2.5 CONTINUE? 1=YES, 0=NO, 2=RESOLUTION ANALYSIS 1 FIT DONE AND WE ARE OUT OF XMJSFT IQUAL AND ICALL ARE 0 7 PLOT FINAL RESULTS: THE SCALE STARTS AT 1.00E+01 FEMTOAMPS AND GOES UP 3 DECADES CHANGE CURRENT SCALE FROM CURRENT VALUE? 1=YES 0=NO 0 gnuplot -e "t= 10.0000000 ; u= 3 " gnutest_L Hit return to continue Write output to file 29? 1=Yes, 0=No. 1 Write numerical output to file 28? 1=Yes, 0=No. 1 *** THIS IS A BEST FIT *** FIT COMPLETED AT 09:54:24 ON Jun 17 3 FIT OF SPECTRA AT TIME 1981 237 12 9 11 986 CUP CHANNELS USED IN FIT BY ABSO A-CUP: *** NO FIT PERFORMED *** B-CUP: CHANNELS 1 - 3 C-CUP: CHANNELS 1 - 3 D-CUP: CHANNELS 1 - 10 CHI SQUARE = 2.54255E+00 CURRENTS WERE GENERATED USING ABSO SINGLE PRECISION CODE WAS USED MASS NQ DEN XDEN VR XVR VPHI XVPHI VZ XVZ W XW 1 1 0.1840 0.0368 -9.7758 6.3399 96.5045 4.7159 58.0640 18.4063 67.6883 2.9752 14 1 0.1199 0.0511 -9.7758 6.3399 96.5045 4.7159 58.0640 18.4063 31.8104 5.9487 PARTICLE VELOCITIES IN S/C COORDINATES (KM/SEC) NCOMP VX VY VZ 1 -107.94 -5.77 -23.71 2 -107.94 -5.77 -23.71 PARTICLE VELOCITIES IN RTN COORDINATES (KM/SEC) *** CORRECTED FOR S/C MOTION *** NCOMP VR VT VN 1 40.09 -104.61 15.16 2 40.09 -104.61 15.16 PROJECTION OF FITTED VELOCITIES ALONG CUP NORMALS (KM/SEC) NCOMP VA VB VC VD 1 -55.24 8.71 -20.30 82.01 2 -55.24 8.71 -20.30 82.01 PROJECTION OF Magnetic Field ALONG CUP NORMALS (Gamma) BA BB BC BD |B| 0.00 -0.00 -0.00 -0.00 0.00 DO NONLINEAR LEAST SQUARES ANALYSIS WITH CURRENT SPECTRA? INPUT NUMBER of ITERATIONS. A negative number uses unit 15 as a remote input file ^C jwb@faraday.mit.edu[34]$ exit exit Script done on Sat 17 Jun 2023 09:54:29 AM ED