Script started on Sat 17 Jun 2023 08:06:03 AM ED jwb@faraday.mit.edu[35]$ mjs.sat Enter the spacecraft id (1 - Voyager 1; 2 - Voyager 2): 1 INPUT IPLNT(0,1,2,3,4 CRU JUP SAT URA NEPT) 2 ======================================== Encounter Mode (Spectral tape) ======================================== Trajectory file selection: 0 ==> Do not mount trajectory file 1 ==> Use short encounter file (via PHASE2) 1 phase2 0 0 43 0 0 1 1980 316 0 0 30 412 CUP RESPONSE AT NORMAL INCIDENCE 66.10 56.24 *** SATURN DATA DISPLAY *** SEDR DATA FILE COVERS: SPECTRAL DATA FILE STARTS AT: V1 - 0 0 0 0 TO 0 0 0 0 V1 - 1980 316 0 0 Do joint ion/electron analysis? 2=M, E1, E2; 1=L, E1, E2; 0=NO 0 Select Data Mode: 1 = Plasma, 2 = DC Return, 3 = MODCAL and CURCAL, 4 = All 1 Integrate Plasma Data? (Analysis Skipped) 2=YES for DC return spectra 1=YES for plasma spectra 0=NO 0 Select Spectral Type: 0 = all, 1 = ions only, 2 = electrons only 3 = L only, 4 = M only, 5 = E1 only, 6 = E2 only, 7 = LS, E1S, E2S only 3 INPUT START TIME: IYR, IDAY, IHR, IMIN, ISEC, IMSEC 1980 318 2 56 59 0 Input number of spectra to average (0= no ave.) 0 CAP 0.15 GAIN 2.00 CLOCK 0.21 V0 THRESHOLD fact1 fact2 JCLK 453.00 124.04 124.04 124.04 2 phase2********** 257 0 0 0 1980 318 2 56 59 564 TIME OF CURRENT SPECTRUM IS 1980 318 2 56 59 564 CURRENT SPECTRUM IS AN L-MODE Distance to Titan center =********* = altitude of ********* MODULATOR ON, PLASMA, NORMAL SUPPRESSOR PLOT JUST DATA? (NO FIT YET) 1=YES, 0=NO 1 THRESHOLD IS 1.2631E+02 FEMTOAMPS. SATURATION IS 1.2184E+06 FEMTOAMPS. MINIMUM AND MAXIMUM CURRENTS (IN FEMTOAMPS) ARE: 1.810E+03 9.819E+03 IN CUP 1 2.016E+03 1.876E+04 IN CUP 2 2.414E+03 2.502E+04 IN CUP 3 3.994E+03 8.814E+04 IN CUP 4 WRITE OUT ALL CURRENTS? 1=YES, 0=NO 0 THE SCALE STARTS AT 1.00E-01 FEMTOAMPS AND GOES UP 6 DECADES CHANGE CURRENT SCALE FROM CURRENT VALUE? 1=YES 0=NO 1 YB (MUST BE A POWER OF 10),IDEC (NUMBER OF DECADES) 1000,2 gnuplot -e "t= 1000.00000 ; u= 2 " gnutest_L Hit return to continue CONTINUE WITH ANALYSIS? 1 for YES, 0 for NO 1 DO NONLINEAR LEAST SQUARES ANALYSIS WITH CURRENT SPECTRA? INPUT NUMBER of ITERATIONS. A negative number uses unit 15 as a remote input file 1 SELECT FITTING OPTION: if negative calculate current 0 ==> DO NOT DO FIT 1 ==> FIT USING PMODEL 3 ==> FIT USING XJC (UNITY RESPONSE) 4 ==> FIT USING ABSO (L OR M MODES - LABCUR,LDCUR) 5 ==> FIT USING ABSOM (M-MODE ONLY - ABCCUR,DCUR) 6 ==> FIT USING ABSO (BIMAXWELLIAN VERSION) 7 ==> FIT USING COLD BEAM (CUPINT,DCPINT) 9 ==> FIT USING VERY COLD BEAM (CUPEXP) GT 10 ==> TERMINATE EXECUTION 6 Correct L mode currents for noise? 1=Yes, 0=No 0 1 ** PARAMETERS FOR USE IN ANALYSIS ** INPUT NUMBER OF COMPONENTS TO FIT TO SPECTRA 2 DO YOU WISH TO HAVE DENSITY AS A FIT PARAMETER? (T OR F) t INDICATE WHICH DENSITIES TO FIT (T OR F FOR EACH OF THE 2 SPECIES) t,t Use CYL coordinates ==> 1 Use S/C coordinates ==> 2 Use RTN coordinates ==> 3 1 INPUT LOGICAL VARIABLES (T OR F ) TO SELECT FIT PARAMETERS FIT VR, VPHI, VZ FOR COMPONENT 1 ? t,t,t FIT THERMAL SPEED FOR THIS COMPONENT ? t INPUT MASS AND CHARGE STATE ( INTEGERS ) OF COMPONENT 1 1.1 INPUT MASS AND CHARGE STATE ( INTEGERS ) OF COMPONENT 1 1,1 INPUT LOGICAL VARIABLES (T OR F ) TO SELECT FIT PARAMETERS FIT VR, VPHI, VZ FOR COMPONENT 2 ? f,f,f FIT THERMAL SPEED FOR THIS COMPONENT ? t INPUT MASS AND CHARGE STATE ( INTEGERS ) OF COMPONENT 2 67 ^? INPUT MASS AND CHARGE STATE ( INTEGERS ) OF COMPONENT 2 16,1 USE ISOTROPIC MAXWELLIANS IN FIT ? f MARQUARDTS PARAMETER (FLAM) IS SET TO 0.1000E+00 THE PARTIAL DERIVATIVE PARAMETER (ALAM) IS SET TO 0.1000E-02 OVERRIDE THESE VALUES ? 1=YES, 0=NO 0 NCOMP CHARGE MASS FIT N FIT VR FIT VPHI FIT VZ FIT W 1 1 1 T T T T T 2 1 16 T F F F T FLAM = 0.100 ALAM = 0.001 ISOTROPIC MAXWELLIAN F SAME TEMPERATURE T CHANGE FIT OPTIONS? 1=YES, 0=NO 0 HOW MANY CONTIGUOUS SETS OF CHANNELS? in cup 1 1 INPUT LOWER AND UPPER CHANNELS FOR SET 1 1 4 HOW MANY CONTIGUOUS SETS OF CHANNELS? in cup 2 1 INPUT LOWER AND UPPER CHANNELS FOR SET 1 1 7 HOW MANY CONTIGUOUS SETS OF CHANNELS? in cup 3 1 INPUT LOWER AND UPPER CHANNELS FOR SET 1 1 8 HOW MANY CONTIGUOUS SETS OF CHANNELS? in cup 4 1 INPUT LOWER AND UPPER CHANNELS FOR SET 1 1 11 VELOCITY IS INITIALIZED TO THAT OF RIGID COROTATION THERMAL SPEEDS INITIALIZED ASSUMING MACH 3 FLOW DENSITIES ESTIMATED FROM DATA IN CUP 4, DIVIDED BY "NCOMP" NCOMP VR VPHI VZ WPAR WPER DEN 1 0.000 48.278 0.000 16.093 16.093 0.000 2 0.000 48.278 0.000 16.093 16.093 0.000 HOW MANY SPECIES DO YOU WISH TO MODIFY FIT PARAMETERS OF? 0=NONE 9=ALL 9 INPUT LOGICAL VARIABLES (T OR F) FOR PARAMETERS YOU WISH CHANGED CHANGE VR,VPHI,VZ,WPAR,WPER,DEN FOR COMPONENT 1 t,t,t,t,t,t INPUT NEW VALUES OF VR,VPHI,VZ,WPAR,WPER,DEN FOR COMPONENT 1 0.000 48.278 0.000 50.000 50.000 5.00 INPUT LOGICAL VARIABLES (T OR F) FOR PARAMETERS YOU WISH CHANGED CHANGE VR,VPHI,VZ,WPAR,WPER,DEN FOR COMPONENT 2 t,t,t,t,t,t INPUT NEW VALUES OF VR,VPHI,VZ,WPAR,WPER,DEN FOR COMPONENT 2 0.000 48.278 0.000 25.000 25.000 15.00 BELOW ARE THE CURRENT VALUES OF THE FIT PARAMETERS NCOMP VR VPHI VZ WPAR WPER DEN 1 0.000 48.278 0.000 50.000 50.000 5.000 2 0.000 48.278 0.000 25.000 25.000 15.000 DO YOU WISH TO MAKE ANY FURTHER CHANGES? 1=YES 0=NO 0 WANT THE BEST FIT DIRECTLY? 1=YES, 0=NO 0 REINITIALIZE FIT MATRICES FROM PREVIOUS SESSION? 1=YES, 0=NO 0 FIRST CALL TO XFNCDV TO INITIALIZE FITTING RUN CHISQR USING FIRST GUESS NO ITERATIONS: 67558.7 CONTINUE? 1=YES, 0=NO, 2=RESOLUTION ANALYSIS 1 PLOT ITERATION 0? (PLOT 0 IS NO ITERATION: USES INITIAL GUESS AND MODEL CURRENTS FROM THAT GUESS) 1=YES, 0=NO 1 THE SCALE STARTS AT 1.00E+03 FEMTOAMPS AND GOES UP 2 DECADES CHANGE CURRENT SCALE FROM CURRENT VALUE? 1=YES 0=NO0 gnuplot -e "t= 1000.00000 ; u= 2 " gnutest_L Hit return to continue AT 6677 0 1 PARAMETERS BEFORE/AFTER ITERATION 1 AND % CHANGE 5.00 15.00 0.00 48.28 0.00 50.00 50.00 25.00 25.00 4.91 16.73 10.14 52.72 -3.65 50.86 54.27 22.11 29.95 -1.72 11.56 Infinity 9.20 -Infinity 1.72 8.54 -11.57 19.80 CONTINUE TO NEXT ITERATION 1=YES; 0=NO 1 ANOTHER CALL TO XFNCDV TO SET UP ITERATION 2 *** NOTE DECREASE IN CHI SQUARE IN ITERATION 1 **** IN ITERATION 1 CHI SQUARE DECREASED FROM 67558.7 TO 11597.8, PERCENT DECREASE: -82.83 DELTA IS 0.83 GOAL IS TO GET BELOW 0.10 VALUE OF FLAMDA IS 0.01000000 CONTINUING ITERATION NUMBER 2 AFTER TOTAL NUMBER OF CALLS TO XFNCDV OF: 2 PREVIOUS CHI SQUARE = 11597.8 CONTINUE? 1=YES, 0=NO, 2=RESOLUTION ANALYSIS 1 PLOT ITERATION 1? 1=YES, 0=NO 1 THE SCALE STARTS AT 1.00E+03 FEMTOAMPS AND GOES UP 2 DECADES CHANGE CURRENT SCALE FROM CURRENT VALUE? 1=YES 0=NO0 gnuplot -e "t= 1000.00000 ; u= 2 " gnutest_L Hit return to continue AT 6677 1 2 PARAMETERS BEFORE/AFTER ITERATION 2 AND % CHANGE 4.91 16.73 10.14 52.72 -3.65 50.86 54.27 22.11 29.95 5.12 17.25 6.96 47.99 -3.70 48.69 50.51 21.43 28.64 4.26 3.06 -31.36 -8.97 -1.58 -4.26 -6.94 -3.07 -4.37 CONTINUE TO NEXT ITERATION 1=YES; 0=NO 1 ANOTHER CALL TO XFNCDV TO SET UP ITERATION 3 *** NOTE DECREASE IN CHI SQUARE IN ITERATION 2 **** IN ITERATION 2 CHI SQUARE DECREASED FROM 11597.8 TO 1487.9, PERCENT DECREASE: -87.17 DELTA IS 0.87 GOAL IS TO GET BELOW 0.10 VALUE OF FLAMDA IS 0.00100000 CONTINUING ITERATION NUMBER 3 AFTER TOTAL NUMBER OF CALLS TO XFNCDV OF: 3 PREVIOUS CHI SQUARE = 1487.9 CONTINUE? 1=YES, 0=NO, 2=RESOLUTION ANALYSIS 1 PLOT ITERATION 2? 1=YES, 0=NO 1 THE SCALE STARTS AT 1.00E+03 FEMTOAMPS AND GOES UP 2 DECADES CHANGE CURRENT SCALE FROM CURRENT VALUE? 1=YES 0=NO0 gnuplot -e "t= 1000.00000 ; u= 2 " gnutest_L Hit return to continue AT 6677 2 3 PARAMETERS BEFORE/AFTER ITERATION 3 AND % CHANGE 5.12 17.25 6.96 47.99 -3.70 48.69 50.51 21.43 28.64 4.95 16.09 10.33 48.65 -8.10 50.30 50.65 22.83 26.20 -3.31 -6.69 48.56 1.38 -118.74 3.30 0.27 6.52 -8.52 CONTINUE TO NEXT ITERATION 1=YES; 0=NO 1 ANOTHER CALL TO XFNCDV TO SET UP ITERATION 4 *** NOTE DECREASE IN CHI SQUARE IN ITERATION 3 **** IN ITERATION 3 CHI SQUARE DECREASED FROM 1487.9 TO 1083.8, PERCENT DECREASE: -27.16 DELTA IS 0.27 GOAL IS TO GET BELOW 0.10 VALUE OF FLAMDA IS 0.00010000 CONTINUING ITERATION NUMBER 4 AFTER TOTAL NUMBER OF CALLS TO XFNCDV OF: 4 PREVIOUS CHI SQUARE = 1083.8 CONTINUE? 1=YES, 0=NO, 2=RESOLUTION ANALYSIS 1 PLOT ITERATION 3? 1=YES, 0=NO 1 THE SCALE STARTS AT 1.00E+03 FEMTOAMPS AND GOES UP 2 DECADES CHANGE CURRENT SCALE FROM CURRENT VALUE? 1=YES 0=NO0 gnuplot -e "t= 1000.00000 ; u= 2 " gnutest_L Hit return to continue AT 6677 3 4 PARAMETERS BEFORE/AFTER ITERATION 4 AND % CHANGE 4.95 16.09 10.33 48.65 -8.10 50.30 50.65 22.83 26.20 4.98 16.13 10.13 47.70 -9.83 50.29 50.70 23.23 25.81 0.49 0.22 -2.00 -1.96 -21.28 -0.01 0.11 1.76 -1.49 CONTINUE TO NEXT ITERATION 1=YES; 0=NO 1 ANOTHER CALL TO XFNCDV TO SET UP ITERATION 5 *** NOTE DECREASE IN CHI SQUARE IN ITERATION 4 **** IN ITERATION 4 CHI SQUARE DECREASED FROM 1083.8 TO 1040.1, PERCENT DECREASE: -4.03 DELTA IS 0.04 GOAL IS TO GET BELOW 0.10 VALUE OF FLAMDA IS 0.00001000 CONTINUING ITERATION NUMBER 5 AFTER TOTAL NUMBER OF CALLS TO XFNCDV OF: 5 PREVIOUS CHI SQUARE = 1040.1 CONTINUE? 1=YES, 0=NO, 2=RESOLUTION ANALYSIS 1 FIT DONE AND WE ARE OUT OF XMJSFT IQUAL AND ICALL ARE 0 4 PLOT FINAL RESULTS: THE SCALE STARTS AT 1.00E+03 FEMTOAMPS AND GOES UP 2 DECADES CHANGE CURRENT SCALE FROM CURRENT VALUE? 1=YES 0=NO 0 gnuplot -e "t= 1000.00000 ; u= 2 " gnutest_L Hit return to continue Write output to file 29? 1=Yes, 0=No. 1 Write numerical output to file 28? 1=Yes, 0=No. 1 *** THIS IS A BEST FIT *** FIT COMPLETED AT 08:16:46 ON Jun 17 3 FIT OF SPECTRA AT TIME 1980 318 2 56 59 564 CUP CHANNELS USED IN FIT BY BILAB A-CUP: CHANNELS 1 - 4 B-CUP: CHANNELS 1 - 7 C-CUP: CHANNELS 1 - 8 D-CUP: CHANNELS 1 - 11 CHI SQUARE = 1.04013E+03 CURRENTS WERE GENERATED USING BILAB SINGLE PRECISION CODE WAS USED MASS NQ DEN XDEN VR XVR VPHI XVPHI VZ XVZ WPAR XWPAR WPER XWPER 1 1 4.9781 13.6928 10.1282 1.9257 47.6988 3.3354 -9.8288 4.3880 50.2935 139.1514 50.7000 1.9552 16 1 16.1285 16.7191 10.1282 1.9257 47.6988 3.3354 -9.8288 4.3880 23.2269 23.7297 25.8127 0.9795 PARTICLE VELOCITIES IN S/C COORDINATES (KM/SEC) NCOMP VX VY VZ 1 -23.23 -31.08 -11.77 2 -23.23 -31.08 -11.77 PARTICLE VELOCITIES IN RTN COORDINATES (KM/SEC) *** CORRECTED FOR S/C MOTION *** NCOMP VR VT VN 1 -0.37 47.31 15.37 2 -0.37 47.31 15.37 PROJECTION OF FITTED VELOCITIES ALONG CUP NORMALS (KM/SEC) NCOMP VA VB VC VD 1 -23.26 -9.50 -0.43 37.75 2 -23.26 -9.50 -0.43 37.75 PROJECTION OF Magnetic Field ALONG CUP NORMALS (Gamma) BA BB BC BD |B| 0.00 -0.00 -0.00 -0.00 0.00 DO NONLINEAR LEAST SQUARES ANALYSIS WITH CURRENT SPECTRA? INPUT NUMBER of ITERATIONS. A negative number uses unit 15 as a remote input file ^C jwb@faraday.mit.edu[36]$ exit exit Script done on Sat 17 Jun 2023 08:16:54 AM ED