Script started on Wed 07 Jun 2023 07:08:58 AM EDT jwb@faraday.mit.edu[53]$ mjs.cru Enter the spacecraft id (1 - Voyager 1; 2 - Voyager 2): 2 INPUT IPLNT(0,1,2,3,4 CRU JUP SAT URA NEPT) 0 ======================================== Cruise Mode (Mission tape) ======================================== Trajectory file selection: 0 ==> Do not mount trajectory file 1 ==> Use short cruise file (via PHASE3) 1 CUP RESPONSE AT NORMAL INCIDENCE 66.10 56.24 SSEDR FILE IS ../../../v2/cruise_ssedr/v2_shortsedr_1977.232.00_1979.186.00 DATA FILE IS ../../../v2/vgr/v2_vgr_1978.001.06_1978.120.23 Do joint ion/electron analysis? 2=M, E1, E2; 1=L, E1, E2; 0=NO 0 Select Data Mode: 1 = Plasma, 2 = DC Return, 3 = MODCAL and CURCAL, 4 = All 1 Integrate Plasma Data? (Analysis Skipped) 2=YES for DC return spectra 1=YES for plasma spectra 0=NO 0 Select Spectral Type: 0 = all, 1 = ions only, 2 = electrons only 3 = L only, 4 = M only, 5 = E1 only, 6 = E2 only, 7 = LS, E1S, E2S only 4 INPUT START TIME: IYR, IDAY, IHR, IMIN, ISEC, IMSEC 1978 11 5 54 34 976 Input number of spectra to average (0= no ave.) 0 TIME OF CURRENT SPECTRUM IS 1978 11 5 54 34 976 CURRENT SPECTRUM IS AN M-MODE PROJECTION OF Magnetic Field ALONG CUP NORMALS (Gamma) BA BB BC BD B mag 1.504 1.263 1.525 -0.056 1.600 MODULATOR ON, PLASMA, NORMAL SUPPRESSOR PLOT JUST DATA? (NO FIT YET) 1=YES, 0=NO 0 CONTINUE WITH ANALYSIS? 1 for YES, 0 for NO 1 DO NONLINEAR LEAST SQUARES ANALYSIS WITH CURRENT SPECTRA? INPUT NUMBER of ITERATIONS. A negative number uses unit 15 as a remote input file 1 SELECT FITTING OPTION: if negative calculate current 0 ==> DO NOT DO FIT 1 ==> FIT USING PMODEL 3 ==> FIT USING XJC (UNITY RESPONSE) 4 ==> FIT USING ABSO (L OR M MODES - LABCUR,LDCUR) 5 ==> FIT USING ABSOM (M-MODE ONLY - ABCCUR,DCUR) 6 ==> FIT USING ABSO (BIMAXWELLIAN VERSION) 7 ==> FIT USING COLD BEAM (CUPINT,DCPINT) 9 ==> FIT USING VERY COLD BEAM (CUPEXP) GT 10 ==> TERMINATE EXECUTION 4 1 ** PARAMETERS FOR USE IN ANALYSIS ** INPUT NUMBER OF COMPONENTS TO FIT TO SPECTRA 3 DO YOU WISH TO HAVE DENSITY AS A FIT PARAMETER? (T OR F) t INDICATE WHICH DENSITIES TO FIT (T OR F FOR EACH OF THE 3 SPECIES) t,t,t Use ECL50 coordinates ==> 1 Use S/C coordinates ==> 2 Use RTN coordinates ==> 3 Use RNP Interstellar Coordinates ==> 4 3 INPUT LOGICAL VARIABLES (T OR F ) TO SELECT FIT PARAMETERS FIT VR, VPHI, VZ FOR COMPONENT 1 ? t,t,t FIT THERMAL SPEED FOR THIS COMPONENT ? t INPUT MASS AND CHARGE STATE ( INTEGERS ) OF COMPONENT 1 1,1 INPUT LOGICAL VARIABLES (T OR F ) TO SELECT FIT PARAMETERS FIT VR, VPHI, VZ FOR COMPONENT 2 ? t,t,t FIT THERMAL SPEED FOR THIS COMPONENT ? t INPUT MASS AND CHARGE STATE ( INTEGERS ) OF COMPONENT 2 1,1 INPUT LOGICAL VARIABLES (T OR F ) TO SELECT FIT PARAMETERS FIT VR, VPHI, VZ FOR COMPONENT 3 ? t,t,t FIT THERMAL SPEED FOR THIS COMPONENT ? t INPUT MASS AND CHARGE STATE ( INTEGERS ) OF COMPONENT 3 4,2 USE ISOTROPIC MAXWELLIANS IN FIT ? t MARQUARDTS PARAMETER (FLAM) IS SET TO 0.1000E+00 THE PARTIAL DERIVATIVE PARAMETER (ALAM) IS SET TO 0.1000E-02 OVERRIDE THESE VALUES ? 1=YES, 0=NO 0 NCOMP CHARGE MASS FIT N FIT VR FIT VPHI FIT VZ FIT W 1 1 1 T T T T T 2 1 1 T T T T T 3 2 4 T T T T T FLAM = 0.100 ALAM = 0.001 ISOTROPIC MAXWELLIAN T SAME TEMPERATURE T CHANGE FIT OPTIONS? 1=YES, 0=NO 0 HOW MANY CONTIGUOUS SETS OF CHANNELS? in cup 1 2 INPUT LOWER AND UPPER CHANNELS FOR SET 1 82 92 INPUT LOWER AND UPPER CHANNELS FOR SET 2 105 111 HOW MANY CONTIGUOUS SETS OF CHANNELS? in cup 2 2 INPUT LOWER AND UPPER CHANNELS FOR SET 1 69 81 INPUT LOWER AND UPPER CHANNELS FOR SET 2 96 100 HOW MANY CONTIGUOUS SETS OF CHANNELS? in cup 3 2 INPUT LOWER AND UPPER CHANNELS FOR SET 1 69 83 INPUT LOWER AND UPPER CHANNELS FOR SET 2 95 100 HOW MANY CONTIGUOUS SETS OF CHANNELS? in cup 4 0 VELOCITY AND 1ST COMPONENT INITIALIZED FROM PROTON FIT PARAMETERS FROM MISSION TAPE NCOMP VR VPHI VZ W DEN 1 504.430 7.455 7.766 35.302 0.445 2 504.430 7.455 7.766 35.302 0.006 3 504.430 7.455 7.766 35.302 0.000 HOW MANY SPECIES DO YOU WISH TO MODIFY FIT PARAMETERS OF? 0=NONE 9=ALL 9 INPUT LOGICAL VARIABLES (T OR F) FOR PARAMETERS YOU WISH CHANGED CHANGE VR,VPHI,VZ,W,DEN FOR COMPONENT 1 t,t,t ,t,t INPUT NEW VALUES OF VR,VPHI,VZ,WPAR,DEN FOR COMPONENT 1 490.000 0.000 8.000 15.000 0.400 INPUT LOGICAL VARIABLES (T OR F) FOR PARAMETERS YOU WISH CHANGED CHANGE VR,VPHI,VZ,W,DEN FOR COMPONENT 2 t,t,t,t,t INPUT NEW VALUES OF VR,VPHI,VZ,WPAR,DEN FOR COMPONENT 2 540.000 -9.000 7.000 30.000 0.100 INPUT LOGICAL VARIABLES (T OR F) FOR PARAMETERS YOU WISH CHANGED CHANGE VR,VPHI,VZ,W,DEN FOR COMPONENT 3 t,t,t,t,t INPUT NEW VALUES OF VR,VPHI,VZ,WPAR,DEN FOR COMPONENT 3 540.000 4.000 9.000 30.000 0.010 BELOW ARE THE CURRENT VALUES OF THE FIT PARAMETERS NCOMP VR VPHI VZ W DEN 1 490.000 0.000 8.000 15.000 0.400 2 540.000 -9.000 7.000 30.000 0.100 3 540.000 4.000 9.000 30.000 0.010 DO YOU WISH TO MAKE ANY FURTHER CHANGES? 1=YES 0=NO 0 WANT THE BEST FIT DIRECTLY? 1=YES, 0=NO 0 REINITIALIZE FIT MATRICES FROM PREVIOUS SESSION? 1=YES, 0=NO 0 FIRST CALL TO XFNCDV TO INITIALIZE FITTING RUN CHISQR USING FIRST GUESS NO ITERATIONS: 936.3 CONTINUE? 1=YES, 0=NO, 2=RESOLUTION ANALYSIS 1 PLOT ITERATION 0? (PLOT 0 IS NO ITERATION: USES INITIAL GUESS AND MODEL CURRENTS FROM THAT GUESS) 1=YES, 0=NO 0 PARAMETERS BEFORE/AFTER ITERATION 1 AND % CHANGE 0.4 0.1 0.0 490.0 0.0 8.0 540.0 -9.0 7.0 540.0 4.0 9.0 15.0 30.0 30.0 0.3 0.1 0.0 492.2 2.0 8.9 538.6 -13.4 7.4 536.7 -6.9 41.1 17.2 32.8 31.8 -15.30 27.39 6.69 0.45 Infinity 11.68 -0.26 -49.21 5.29 -0.62 -272.68 356.20 14.38 9.22 5.91 CONTINUE TO NEXT ITERATION 1=YES; 0=NO 1 ANOTHER CALL TO XFNCDV TO SET UP ITERATION 2 *** NOTE DECREASE IN CHI SQUARE IN ITERATION 1 **** IN ITERATION 1 CHI SQUARE DECREASED FROM 936.3 TO 59.2, PERCENT DECREASE: -93.68 DELTA IS 0.94 GOAL IS TO GET BELOW 0.10 VALUE OF FLAMDA IS 0.01000000 CONTINUING ITERATION NUMBER 2 AFTER TOTAL NUMBER OF CALLS TO XFNCDV OF: 2 PREVIOUS CHI SQUARE = 59.2 CONTINUE? 1=YES, 0=NO, 2=RESOLUTION ANALYSIS 1 PLOT ITERATION 1? 1=YES, 0=NO 0 PARAMETERS BEFORE/AFTER ITERATION 2 AND % CHANGE 0.3 0.1 0.0 492.2 2.0 8.9 538.6 -13.4 7.4 536.7 -6.9 41.1 17.2 32.8 31.8 0.3 0.1 0.0 494.1 4.4 9.1 541.4 -9.1 6.8 535.7 -9.6 38.6 17.7 35.2 32.1 -1.21 4.53 4.60 0.38 116.57 1.65 0.52 32.57 -7.72 -0.18 -39.56 -6.00 3.12 7.54 0.87 CONTINUE TO NEXT ITERATION 1=YES; 0=NO 1 ANOTHER CALL TO XFNCDV TO SET UP ITERATION 3 *** NOTE DECREASE IN CHI SQUARE IN ITERATION 2 **** IN ITERATION 2 CHI SQUARE DECREASED FROM 59.2 TO 13.1, PERCENT DECREASE: -77.79 DELTA IS 0.78 GOAL IS TO GET BELOW 0.10 VALUE OF FLAMDA IS 0.00100000 CONTINUING ITERATION NUMBER 3 AFTER TOTAL NUMBER OF CALLS TO XFNCDV OF: 3 PREVIOUS CHI SQUARE = 13.1 CONTINUE? 1=YES, 0=NO, 2=RESOLUTION ANALYSIS 1 PLOT ITERATION 2? 1=YES, 0=NO 0 PARAMETERS BEFORE/AFTER ITERATION 3 AND % CHANGE 0.3 0.1 0.0 494.1 4.4 9.1 541.4 -9.1 6.8 535.7 -9.6 38.6 17.7 35.2 32.1 0.3 0.1 0.0 494.2 4.4 9.3 542.8 -8.8 7.7 535.5 -9.6 39.1 17.8 33.4 32.0 1.66 -4.75 0.08 0.04 1.37 2.02 0.26 3.16 13.18 -0.03 0.68 1.32 0.47 -5.23 -0.12 CONTINUE TO NEXT ITERATION 1=YES; 0=NO 1 ANOTHER CALL TO XFNCDV TO SET UP ITERATION 4 *** NOTE DECREASE IN CHI SQUARE IN ITERATION 3 **** IN ITERATION 3 CHI SQUARE DECREASED FROM 13.1 TO 12.8, PERCENT DECREASE: -2.66 DELTA IS 0.03 GOAL IS TO GET BELOW 0.10 VALUE OF FLAMDA IS 0.00010000 CONTINUING ITERATION NUMBER 4 AFTER TOTAL NUMBER OF CALLS TO XFNCDV OF: 4 PREVIOUS CHI SQUARE = 12.8 CONTINUE? 1=YES, 0=NO, 2=RESOLUTION ANALYSIS 1 FIT DONE AND WE ARE OUT OF XMJSFT IQUAL AND ICALL ARE 0 3 PLOT FINAL RESULTS: THE SCALE STARTS AT 1.00E-01 FEMTOAMPS AND GOES UP 6 DECADES CHANGE CURRENT SCALE FROM CURRENT VALUE? 1=YES 0=NO 1 YB (MUST BE A POWER OF 10),IDEC (NUMBER OF DECADES) 100,3 gnuplot -e "t= 100.000000 ; u= 3 " gnutest_M Hit return to continue Write output to file 29? 1=Yes, 0=No. 1 Write numerical output to file 28? 1=Yes, 0=No. 1 *** THIS IS A BEST FIT *** FIT COMPLETED AT 07:15:51 ON Jun 7 3 FIT OF SPECTRA AT TIME 1978. 11. 5. 54. 34. 976. CUP CHANNELS USED IN FIT BY ABSO A-CUP: CHANNELS 82 - 92 CHANNELS 105 -111 B-CUP: CHANNELS 69 - 81 CHANNELS 96 -100 C-CUP: CHANNELS 69 - 83 CHANNELS 95 -100 D-CUP: *** NO FIT PERFORMED *** CHI SQUARE = 1.27933E+01 CURRENTS WERE GENERATED USING ABSO SINGLE PRECISION CODE WAS USED MASS NQ DEN XDEN Vr XVr Vt XVt Vn XVn W XW 1 1 0.3403 0.0099 494.2411 0.2602 4.4223 0.5130 9.2654 0.6912 17.7764 0.3033 1 1 0.1268 0.0130 542.8430 2.0221 -8.7689 3.5727 7.6971 4.6683 33.3942 3.9481 4 2 0.0112 0.0027 535.5438 6.9657 -9.5738 20.8094 39.1037 30.4354 32.0117 10.2953 PARTICLE VELOCITIES IN S/C COORDINATES (KM/SEC) NCOMP VX VY VZ 1 162.09 65.69 445.42 2 171.30 63.78 494.92 3 150.98 88.62 491.71 PARTICLE VELOCITIES IN RTN COORDINATES (KM/SEC) *** CORRECTED FOR S/C MOTION *** NCOMP VR VT VN 1 494.23 4.42 9.27 2 542.84 -8.77 7.70 3 535.54 -9.57 39.10 PROJECTION OF FITTED VELOCITIES ALONG CUP NORMALS (KM/SEC) NCOMP VA VB VC VD 1 477.81 381.79 396.10 -147.72 2 526.72 425.24 443.26 -151.42 3 521.94 432.50 431.75 -153.61 PROJECTION OF Magnetic Field ALONG CUP NORMALS (Gamma) BA BB BC BD |B| 1.50 1.26 1.53 -0.06 1.60 DO NONLINEAR LEAST SQUARES ANALYSIS WITH CURRENT SPECTRA? INPUT NUMBER of ITERATIONS. A negative number uses unit 15 as a remote input file ^C jwb@faraday.mit.edu[54]$ exit exit Script done on Wed 07 Jun 2023 07:15:56 AM ED