Script started on Sun 13 Aug 2023 12:57:14 PM ED jwb@faraday[63]$ mjs.cru Enter the spacecraft id (1 - Voyager 1; 2 - Voyager 2): 2 INPUT IPLNT(0,1,2,3,4 CRU JUP SAT URA NEPT) 0 ======================================== Cruise Mode (Mission tape) ======================================== Trajectory file selection: 0 ==> Do not mount trajectory file 1 ==> Use short cruise file (via PHASE3) 1 CUP RESPONSE AT NORMAL INCIDENCE 66.10 56.24 SSEDR FILE IS ../../../v2/cruise_ssedr/v2_shortsedr_1977.232.00_1979.186.00 DATA FILE IS ../../../v2/vgr/v2_vgr_1977.233.03_1977.365.23 Do joint ion/electron analysis? 2=M, E1, E2; 1=L, E1, E2; 0=NO 0 Select Data Mode: 1 = Plasma, 2 = DC Return, 3 = MODCAL and CURCAL, 4 = All 1 Integrate Plasma Data? (Analysis Skipped) 2=YES for DC return spectra 1=YES for plasma spectra 0=NO 0 Select Spectral Type: 0 = all, 1 = ions only, 2 = electrons only 3 = L only, 4 = M only, 5 = E1 only, 6 = E2 only, 7 = LS, E1S, E2S only 3 INPUT START TIME: IYR, IDAY, IHR, IMIN, ISEC, IMSEC 1977 304 4 57 50 852 Input number of spectra to average (0= no ave.) 0 CAP 1.15 GAIN 2.00 CLOCK 0.21 V0 THRESHOLD 372.00 1018.57 TIME OF CURRENT SPECTRUM IS 1977 304 4 57 50 852 CURRENT SPECTRUM IS AN L-MODE PROJECTION OF Magnetic Field ALONG CUP NORMALS (Gamma) BA BB BC BD B mag 2.122 2.130 2.227 0.224 2.307 MODULATOR ON, PLASMA, NORMAL SUPPRESSOR PLOT JUST DATA? (NO FIT YET) 1=YES, 0=NO 0 CONTINUE WITH ANALYSIS? 1 for YES, 0 for NO 1 DO NONLINEAR LEAST SQUARES ANALYSIS WITH CURRENT SPECTRA? INPUT NUMBER of ITERATIONS. A negative number uses unit 15 as a remote input file 1 SELECT FITTING OPTION: if negative calculate current 0 ==> DO NOT DO FIT 1 ==> FIT USING PMODEL 3 ==> FIT USING XJC (UNITY RESPONSE) 4 ==> FIT USING ABSO (L OR M MODES - LABCUR,LDCUR) 5 ==> FIT USING ABSOM (M-MODE ONLY - ABCCUR,DCUR) 6 ==> FIT USING ABSO (BIMAXWELLIAN VERSION) 7 ==> FIT USING COLD BEAM (CUPINT,DCPINT) 9 ==> FIT USING VERY COLD BEAM (CUPEXP) GT 10 ==> TERMINATE EXECUTION 3 Correct L mode currents for noise? 1=Yes, 0=No 0 1 ** PARAMETERS FOR USE IN ANALYSIS ** INPUT NUMBER OF COMPONENTS TO FIT TO SPECTRA 2 DO YOU WISH TO HAVE DENSITY AS A FIT PARAMETER? (T OR F) t INDICATE WHICH DENSITIES TO FIT (T OR F FOR EACH OF THE 2 SPECIES) t,t Use ECL50 coordinates ==> 1 Use S/C coordinates ==> 2 Use RTN coordinates ==> 3 Use RNP Interstellar Coordinates ==> 4 3 INPUT LOGICAL VARIABLES (T OR F ) TO SELECT FIT PARAMETERS FIT VR, VPHI, VZ FOR COMPONENT 1 ? t,t,t FIT THERMAL SPEED FOR THIS COMPONENT ? t INPUT MASS AND CHARGE STATE ( INTEGERS ) OF COMPONENT 1 1,1 INPUT LOGICAL VARIABLES (T OR F ) TO SELECT FIT PARAMETERS FIT VR, VPHI, VZ FOR COMPONENT 2 ? f,f,f FIT THERMAL SPEED FOR THIS COMPONENT ? t INPUT MASS AND CHARGE STATE ( INTEGERS ) OF COMPONENT 2 4,2 USE ISOTROPIC MAXWELLIANS IN FIT ? t MARQUARDTS PARAMETER (FLAM) IS SET TO 0.1000E+00 THE PARTIAL DERIVATIVE PARAMETER (ALAM) IS SET TO 0.1000E-02 OVERRIDE THESE VALUES ? 1=YES, 0=NO 0 NCOMP CHARGE MASS FIT N FIT VR FIT VPHI FIT VZ FIT W 1 1 1 T T T T T 2 2 4 T F F F T FLAM = 0.100 ALAM = 0.001 ISOTROPIC MAXWELLIAN T SAME TEMPERATURE T CHANGE FIT OPTIONS? 1=YES, 0=NO 0 HOW MANY CONTIGUOUS SETS OF CHANNELS? in cup 1 1 INPUT LOWER AND UPPER CHANNELS FOR SET 1 6 10 HOW MANY CONTIGUOUS SETS OF CHANNELS? in cup 2 1 INPUT LOWER AND UPPER CHANNELS FOR SET 1 6 10 HOW MANY CONTIGUOUS SETS OF CHANNELS? in cup 3 1 INPUT LOWER AND UPPER CHANNELS FOR SET 1 6 10 HOW MANY CONTIGUOUS SETS OF CHANNELS? in cup 4 0 VELOCITY AND 1ST COMPONENT INITIALIZED FROM PROTON FIT PARAMETERS FROM MISSION TAPE NCOMP VR VPHI VZ W DEN 1 332.810 11.834 20.550 31.063 11.094 2 332.810 11.834 20.550 31.063********** HOW MANY SPECIES DO YOU WISH TO MODIFY FIT PARAMETERS OF? 0=NONE 9=ALL 9 INPUT LOGICAL VARIABLES (T OR F) FOR PARAMETERS YOU WISH CHANGED CHANGE VR,VPHI,VZ,W,DEN FOR COMPONENT 1 f,f,f,f,f INPUT LOGICAL VARIABLES (T OR F) FOR PARAMETERS YOU WISH CHANGED CHANGE VR,VPHI,VZ,W,DEN FOR COMPONENT 2 f,f,f,f,t INPUT NEW VALUE OF DEN FOR COMPONENT 2 2 BELOW ARE THE CURRENT VALUES OF THE FIT PARAMETERS NCOMP VR VPHI VZ W DEN 1 332.810 11.834 20.550 31.063 11.094 2 332.810 11.834 20.550 31.063 2.000 DO YOU WISH TO MAKE ANY FURTHER CHANGES? 1=YES 0=NO 0 WANT THE BEST FIT DIRECTLY? 1=YES, 0=NO 0 REINITIALIZE FIT MATRICES FROM PREVIOUS SESSION? 1=YES, 0=NO 0 FIRST CALL TO XFNCDV TO INITIALIZE FITTING RUN CHISQR USING FIRST GUESS NO ITERATIONS: 84337608.0 CONTINUE? 1=YES, 0=NO, 2=RESOLUTION ANALYSIS 1 PLOT ITERATION 0? (PLOT 0 IS NO ITERATION: USES INITIAL GUESS AND MODEL CURRENTS FROM THAT GUESS) 1=YES, 0=NO 1 THE SCALE STARTS AT 1.00E-01 FEMTOAMPS AND GOES UP 6 DECADES CHANGE CURRENT SCALE FROM CURRENT VALUE? 1=YES 0=NO1 YB (MUST BE A POWER OF 10),IDEC (NUMBER OF DECADES) 1000,4 rm: cannot remove ‘data.txt’: No such file or directory gnuplot -e "t= 1000.00000 ; u= 4 " gnutest_L Hit return to continue AT 6677 0 1 PARAMETERS BEFORE/AFTER ITERATION 1 AND % CHANGE 11.09 2.00 332.81 11.83 20.55 31.06 31.06 10.72 0.50 330.05 11.05 19.44 18.32 33.05 -3.34 -75.06 -0.83 -6.61 -5.42 -41.02 6.39 CONTINUE TO NEXT ITERATION 1=YES; 0=NO 1 ANOTHER CALL TO XFNCDV TO SET UP ITERATION 2 *** NOTE DECREASE IN CHI SQUARE IN ITERATION 1 **** IN ITERATION 1 CHI SQUARE DECREASED FROM 84337608.0 TO 1027350.8, PERCENT DECREASE: -98.78 DELTA IS 0.99 GOAL IS TO GET BELOW 0.10 VALUE OF FLAMDA IS 0.01000000 CONTINUING ITERATION NUMBER 2 AFTER TOTAL NUMBER OF CALLS TO XFNCDV OF: 2 PREVIOUS CHI SQUARE = 1027350.8 CONTINUE? 1=YES, 0=NO, 2=RESOLUTION ANALYSIS 1 PLOT ITERATION 1? 1=YES, 0=NO 1 THE SCALE STARTS AT 1.00E+03 FEMTOAMPS AND GOES UP 4 DECADES CHANGE CURRENT SCALE FROM CURRENT VALUE? 1=YES 0=NO0 gnuplot -e "t= 1000.00000 ; u= 4 " gnutest_L Hit return to continue PARAMETERS BEFORE/AFTER ITERATION 2 AND % CHANGE 10.72 0.50 330.05 11.05 19.44 18.32 33.05 10.54 0.29 329.04 7.99 24.43 16.44 26.36 -1.67 -42.28 -0.31 -27.68 25.72 -10.27 -20.24 CONTINUE TO NEXT ITERATION 1=YES; 0=NO 1 ANOTHER CALL TO XFNCDV TO SET UP ITERATION 3 *** NOTE DECREASE IN CHI SQUARE IN ITERATION 2 **** IN ITERATION 2 CHI SQUARE DECREASED FROM 1027350.8 TO 122775.0, PERCENT DECREASE: -88.05 DELTA IS 0.88 GOAL IS TO GET BELOW 0.10 VALUE OF FLAMDA IS 0.00100000 CONTINUING ITERATION NUMBER 3 AFTER TOTAL NUMBER OF CALLS TO XFNCDV OF: 3 PREVIOUS CHI SQUARE = 122775.0 CONTINUE? 1=YES, 0=NO, 2=RESOLUTION ANALYSIS 1 PLOT ITERATION 2? 1=YES, 0=NO 0 PARAMETERS BEFORE/AFTER ITERATION 3 AND % CHANGE 10.54 0.29 329.04 7.99 24.43 16.44 26.36 10.53 0.29 328.40 7.57 26.06 15.50 24.19 -0.12 2.01 -0.19 -5.33 6.64 -5.74 -8.23 CONTINUE TO NEXT ITERATION 1=YES; 0=NO 1 ANOTHER CALL TO XFNCDV TO SET UP ITERATION 4 *** NOTE DECREASE IN CHI SQUARE IN ITERATION 3 **** IN ITERATION 3 CHI SQUARE DECREASED FROM 122775.0 TO 47472.5, PERCENT DECREASE: -61.33 DELTA IS 0.61 GOAL IS TO GET BELOW 0.10 VALUE OF FLAMDA IS 0.00010000 CONTINUING ITERATION NUMBER 4 AFTER TOTAL NUMBER OF CALLS TO XFNCDV OF: 4 PREVIOUS CHI SQUARE = 47472.5 CONTINUE? 1=YES, 0=NO, 2=RESOLUTION ANALYSIS 1 PLOT ITERATION 3? 1=YES, 0=NO 0 PARAMETERS BEFORE/AFTER ITERATION 4 AND % CHANGE 10.53 0.29 328.40 7.57 26.06 15.50 24.19 10.53 0.29 328.33 7.38 26.40 15.31 24.10 -0.00 -0.43 -0.02 -2.53 1.31 -1.17 -0.37 CONTINUE TO NEXT ITERATION 1=YES; 0=NO 1 ANOTHER CALL TO XFNCDV TO SET UP ITERATION 5 *** NOTE DECREASE IN CHI SQUARE IN ITERATION 4 **** IN ITERATION 4 CHI SQUARE DECREASED FROM 47472.5 TO 45499.9, PERCENT DECREASE: -4.16 DELTA IS 0.04 GOAL IS TO GET BELOW 0.10 VALUE OF FLAMDA IS 0.00001000 CONTINUING ITERATION NUMBER 5 AFTER TOTAL NUMBER OF CALLS TO XFNCDV OF: 5 PREVIOUS CHI SQUARE = 45499.9 CONTINUE? 1=YES, 0=NO, 2=RESOLUTION ANALYSIS 1 FIT DONE AND WE ARE OUT OF XMJSFT IQUAL AND ICALL ARE 0 4 PLOT FINAL RESULTS: THE SCALE STARTS AT 1.00E+03 FEMTOAMPS AND GOES UP 4 DECADES CHANGE CURRENT SCALE FROM CURRENT VALUE? 1=YES 0=NO 0 gnuplot -e "t= 1000.00000 ; u= 4 " gnutest_L Hit return to continue Write output to file fits? 1=Yes, 0=No. 1 Write numerical output to fits.sh? 1=Yes, 0=No. 1 *** THIS IS A BEST FIT *** FIT COMPLETED AT 13:06:22 ON Aug 13 3 FIT OF SPECTRA AT TIME 1977 304 4 57 50 852 CUP CHANNELS USED IN FIT BY XJC(UR) A-CUP: CHANNELS 6 - 10 B-CUP: CHANNELS 6 - 10 C-CUP: CHANNELS 6 - 10 D-CUP: *** NO FIT PERFORMED *** CHI SQUARE = 4.54999E+04 CURRENTS WERE GENERATED USING XJC(UR) SINGLE PRECISION CODE WAS USED MASS NQ DEN XDEN Vr XVr Vt XVt Vn XVn W XW 1 1 10.5315 0.0510 328.3331 0.6594 7.3765 1.0625 26.3975 1.7449 15.3147 0.4689 4 2 0.2924 0.0396 328.3331 0.6594 7.3765 1.0625 26.3975 1.7449 24.0986 5.5463 PARTICLE VELOCITIES IN S/C COORDINATES (KM/SEC) NCOMP VX VY VZ 1 -89.47 -41.34 299.70 2 -89.47 -41.34 299.70 PARTICLE VELOCITIES IN RTN COORDINATES (KM/SEC) *** CORRECTED FOR S/C MOTION *** NCOMP VR VT VN 1 328.32 7.38 26.40 2 328.32 7.38 26.40 PROJECTION OF FITTED VELOCITIES ALONG CUP NORMALS (KM/SEC) NCOMP VA VB VC VD 1 248.06 301.06 295.76 104.04 2 248.06 301.06 295.76 104.04 PROJECTION OF Magnetic Field ALONG CUP NORMALS (Gamma) BA BB BC BD |B| 2.12 2.13 2.23 0.22 2.31 CONTINUE WITH ANALYSIS? 1 for YES, 0 for NO 0 jwb@faraday[64]$ exit exit Script done on Sun 13 Aug 2023 01:06:29 PM ED