C 04/18/85 07:58:47 04/17/85 16:12:00 $38 SUBROUTINE XCUR(DN,W,U1,A,Z,MODE,NCHN,LCUP,DIST) C C ** MODIFIED TO USE SINGLE PRECISION 5/22/84 JDR *** C C MODIFIED BY RLM TO SIMULATE CURRENTS IN BOTH THE MAIN AND C SIDE SENSORS BY USING THE "RECTANGULAR" AND "SQUARE" C APPROXIMATIONS, RESPECTIVELY. C 12/17/84 C C C THIS SUBROUTINE COMPUTES THE MAIN SENSOR RESPONSE OF THE C VOYAGER PLS EXPERIMENT OPERATING IN EITHER THE M-MODE OR THE C L-MODE TO A PLASMA WHOSE DISTRIBUTION FUNCTION CAN BE MODELED AS A C CONVECTED MAXWELLIAN. IT USES AN ALGORITHM IN WHICH THE C INTEGRATIONS OVER THE COMPONENTS OF VELOCITY PERPENDICULAR TO C THE CUP NORMAL ARE PERFORMED ANALYTICALLY, WHILE THE INTEGRATION C OVER THE COMPONENT OF VELOCITY ALONG THE CUP NORMAL IS DONE C NUMERICALLY. THE ALGORITHM IS DESCRIBED IN DETAIL IN C ALAN BARNETT'S DOCTORAL THESIS. C FOR EACH MODULATOR STEP, THE INTEGRATION OVER THE CHANNEL C WIDTH IS DONE USING SIMPSON'S RULE, WHILE A RECTANGULAR RULE C IS USED FOR THE INTEGRATION OVER THE "TAIL". THE CURRENT IN A C GIVEN CHANNEL IS COMPUTED FROM THE DIFFERENCE BETWEEN THE C INTEGRATED CURRENT FOR ADJACENT MODULATOR GRID STEPS. THE VZ C INTEGRATION IS CUT OFF AT A PREDETERMINED VALUE FOR EACH CHANNEL. C C THE INPUT VARIABLES ARE: C DN DENSITY OF SPECIES (NUMBER/CC) C W THERMAL SPEED (KM/SEC) C U1 BULK FLOW VELOCITY IN CUP COORDINATES (KM/SEC) C A SPECIES MASS (AMU) C Z SPECIES CHARGE (PROTON CHARGES) C MODE 1=L,2=M C NCHN(2) FIRST AND LAST CHANNEL TO BE SIMULATED C LCUP CUP NUMBER: 1=A, 2=B, 3=C, 4=D C C THE OUTPUT VARIABLE IS C DIST(128) REDUCED DISTRIBUTION FUNCTION OR CURRENT C c REAL*8 $$$DT(6) /'$$DATE$$','04/17/85','16 c | ' XCUR',' FORTRAN','MJ INTEGER*4 NFIRST,NCHN(2),NC1,NC2,NCHAN,MODE,MFIRST INTEGER*4 NSTEP(129) C C THE INTEGER CONSTANTS HAVE THE FOLLOWING MEANING C NSTEP(I) NUMBER OF STEPS IN THE NUMERICAL INTEGRATION C BETWEEN THE THESHOLD VOLTAGES FOR CHANNEL I AND I+1 C NFIRST(I) NUMBER OF THE FIRST ELEMENT OF TVZ INCLUDED C IN THE INTEGRATION OF THE NEAR TAIL FOR CHANNEL I C REAL*4 AMA1,AMA2,AMC1,AMSFT,TVZ,TDVZ REAL*4 SD,CCD,AAD REAL*4 AAAVZ,AAVZ,AVZ,AAADVZ,AADVZ,ADVZ,DVOLT,DVOLTL c REAL*4 U(3),ZX(4,2),ZY(4,2),U1(3),AA(2),SX(2),SY(2),SZ(2),CC(2) REAL*4 U(3),ZX(4,2),ZY(4,2),U1(3),AA(2),SX(2),SY(2), CC(2) c REAL*4 A1(2),XBAR(2),A2(2),B(2,2),D(2,2),AC(2),CRR(129) REAL*4 D(2,2),AC(2),CRR(129) REAL*4 AX(2),AY(2) REAL*4 CRNT(129) REAL*4 X(4), , Y(4), , ZD(4) REAL*4 R(4) REAL*4 DIST(128) C C THE REAL CONSTANTS HAVE THE FOLLOWING MEANINGS C X,Y,ZD PARAMETERS FOR TRAPEZOIDAL APPROXIMATION TO SENSITIVE C AREA C R NOMINAL APERTURE AREA C T NOMINAL GRID TRANSPARENCY AT NORMAL INCIDENCE C ECHRGE PROTON CHARGE IN COULOMBS C C C TRANSPARENCY PARAMETERS AND SHIFT FUNCTIONS C COMMON/TRNPAR/AMA1(100,129),AMA2(100,129),AMC1(100,129), , AMSFT(100,129) COMMON/TRNPRD/AAD(100,129,2),CCD(100,129,2),SD(100,129) C C Z-COMPONENTS OF VELOCITY FOR NUMERICAL INTEGRATION C COMMON/VZ/AAAVZ(22,5),AAVZ(4,40),AVZ(2,84),AAADVZ(22,5), , AADVZ(4,40),ADVZ(2,84),DVOLT(128),NFIRST(129),MFIRST(129) COMMON/TAIL/TVZ(241),TDVZ(241) COMMON/LCOMP/DVOLTL(16),NM(129),NL(17) real t(4) data X/-4.94E0,-1.10E0,1.10E0,4.94E0/, , Y/-3.63E0,-2.02E0,0.048E0,2.29E0/, , ZD/-1.61E0,-0.106E0,0.106E0,1.61E0/ data R/3*100.,82.7/ data T/3*.65,.6801/ data ECHRGE/1.6D-19/,SQRTPI/1.77245385/ data NSTEP/22,16,10,6,41*4,84*2/ C C COMMON BLOCKS TRNPAR, VZ, TAIL, AND LCOMP ARE FILLED BY SUBROUTINE C CONRD, WHICH MUST BE CALLED BEFORE THE FIRST CALL TO LABCUR. C THE VARIABLES HAVE THE FOLLOWING MEANINGS C AMA1 CONSTANTS C AMA2 WHICH DESCRIBE THE CUP C AMC1 TRANSPARENCY C AMSFT THE SHIFT FUNCTION C THE FIRST INDEX OF THE PRECEDING FOUR VARIABLES REFERS TO THE C STEP NUMBER IN THE VZ INTEGRATION; THE SECOND INDEX C REFERS TO THE MODULATOR STEP NUMBER. C C AAAVZ VALUES OF VZ FOR INTEGRATION ACROSS C CHANNELS 1-5 C AAVZ VALUES OF VZ FOR INTEGRATION ACROSS C CHANNELS 6-45 C AVZ VALUES OF VZ FOR INTEGRATION ACROSS C CHANNELS 46-129 C AAADVZ WEIGHTS FOR SIMPSON INTEGRATION ACROSS C CHANNELS 1-5 C AADVZ WEIGHTS FOR SIMPSON INTEGRATION ACROSS C CHANNELS 6-45 C ADVZ WEIGHTS FOR SIMPSON INTEGRATION ACROSS C CHANNELS 46-129 C DVOLT VOLTAGE WIDTHS OF THE M-MODE CHANNELS C DVOLTL VOLTAGE WIDTHS OF THE L-MODE CHANNELS C NM(I) NUMBER OF INTEGRATION STEPS INCLUDED C WHEN STEP I IS UPPER THRESHOLD (M-MODE) C NL(I) NUMBER OF INTEGRATION STEPS INCLUDED C WHEN STEP I IS UPPER THRESHOLD (L-MODE) C TVZ TABLE OF VALUES OF VZ FOR INTEGRATION OF C THE TAIL C TDVZ TABLE OF WEIGHTS FOR NUMERICAL INTEGRATION C OF THE TAIL C C FUNCTION FOR EVALUATION OF TRANSVERSE INTEGRALS C UPS(Z1,Z2,Z3,Z4)=(PHI(Z4)-PHI(Z3))/(Z4-Z3) + -(PHI(Z1)-PHI(Z2))/(Z1-Z2) C C DEFINE CONST AND COMPUTE NORMALIZED BULK VELOCITY C C CONST = R(LCUP)*T(LCUP)*Z*ECHRGE*1.E20/SQRTPI*DN NC1=NCHN(1) NC2=NCHN(2) NC3=NC2+1 DO 1 I=1,3 1 U(I)=U1(I)/W C C ENTER OUTER LOOP OVER MODULATOR STEPS C DO 5000 NCN=NC1,NC3 NCHAN=NCN IF(MODE .EQ. 1) NCHAN=1+8*(NCN-1) C C INITIALIZE CURENT C CURENT=0.E0 DO 2600 JJ=1,100 C C LAST INTEGRATION POINT NOT NEEDED; SKIP LOOP IF APPROPRIATE C IF (NCN .EQ. NC3 .AND. JJ .GT. NL(NCN) .AND. MODE .EQ. 1) + GO TO 2600 IF (NCN .EQ. NC3 .AND. JJ .GT. NM(NCN) .AND. MODE .EQ. 2) + GO TO 2600 C C INITIALIZE G AND CHOOSE PROPER VALUE OF VZ, DVZ C G=0.E0 IF(NCHAN .GE. 6 .AND. NCHAN .LE. 45)GO TO 100 IF(NCHAN .GE. 46)GO TO 200 IF(JJ .GT. NSTEP(NCHAN)) GO TO 10 VZ=AAAVZ(JJ,NCHAN)*SQRT(Z/A)/W DVZ=AAADVZ(JJ,NCHAN)*SQRT(Z/A) GO TO 1000 10 N=JJ-NSTEP(NCHAN)+NFIRST(NCHAN)-1 VZ=TVZ(N)*SQRT(Z/A)/W DVZ=TDVZ(N)*SQRT(Z/A) GO TO 1000 100 IF(JJ .GT. 4) GO TO 110 VZ=AAVZ(JJ,NCHAN-5)*SQRT(Z/A)/W DVZ=AADVZ(JJ,NCHAN-5)*SQRT(Z/A) GO TO 1000 110 N=JJ-5+NFIRST(NCHAN) VZ=TVZ(N)*SQRT(Z/A)/W DVZ=TDVZ(N)*SQRT(Z/A) GO TO 1000 200 IF(JJ .GT. 2) GO TO 210 VZ=AVZ(JJ,NCHAN-45)*SQRT(Z/A)/W DVZ=ADVZ(JJ,NCHAN-45)*SQRT(Z/A) GO TO 1000 210 N=JJ-3+NFIRST(NCHAN) VZ=TVZ(N)*SQRT(Z/A)/W DVZ=TDVZ(N)*SQRT(Z/A) 1000 X1=(VZ-U(3))**2 C C TEST FOR CUTOFF DUE TO MAXWELLIAN DEPENDENCE ON VZ C IF (X1 .GT. 16.E0) GO TO 2590 C C ASSIGN VALUES OF RESPONSE PARAMETERS C IF (LCUP .NE. 4) GO TO 2018 C C PARAMETERS FOR SIDE SENSOR C S=SD(JJ,NCHAN) CC(1)=CCD(JJ,NCHAN,1) AC(1)=AAD(JJ,NCHAN,1) AC(2)=AAD(JJ,NCHAN,2) GO TO 2019 C C PARAMETERS FOR MAIN SENSOR C 2018 S=AMSFT(JJ,NCHAN) CC(1)=AMC1(JJ,NCHAN) AC(1)=AMA1(JJ,NCHAN) AC(2)=AMA2(JJ,NCHAN) 2019 CC(2)=1.0E0-CC(1) AA(1)=(AC(1)+VZ**2)/S**2 AA(2)=(AC(2)+VZ**2)/S**2 SX(1)=S*VZ*U(1)/(VZ*VZ+AC(1)) SX(2)=S*VZ*U(1)/(VZ*VZ+AC(2)) SY(1)=S*VZ*U(2)/(VZ*VZ+AC(1)) SY(2)=S*VZ*U(2)/(VZ*VZ+AC(2)) C C CALCULATE INTEGRAND FOR NUMERICAL INTEGRATION OVER VZ; C FIRST, CHANGE VARIABLES FOR ANALYTIC EVALUATION OF VX INTEGRAL C SECOND, CHANGE VARIABLES FOR ANALYTIC EVALUATION OF VY INTEGRAL C IF (LCUP .EQ. 4) GO TO 2031 DO 2020 L=1,4 ZX(L,1)=SQRT(AA(1))*(X(L)-SX(1)) ZX(L,2)=SQRT(AA(2))*(X(L)-SX(2)) ZY(L,1)=SQRT(AA(1))*(Y(L)-SY(1)) 2020 ZY(L,2)=SQRT(AA(2))*(Y(L)-SY(2)) GO TO 2032 2031 CONTINUE DO 2030 L=1,4 ZX(L,1)=SQRT(AA(1))*(ZD(L)-SX(1)) ZX(L,2)=SQRT(AA(2))*(ZD(L)-SX(2)) ZY(L,1)=SQRT(AA(1))*(ZD(L)-SY(1)) 2030 ZY(L,2)=SQRT(AA(2))*(ZD(L)-SY(2)) 2032 CONTINUE C C EVALUATE INTEGRATION OVER VX C%%% C A1(1)=(PHI(ZX(1,1))+PHI(ZX(4,1))-PHI(ZX(3,1))-PHI(ZX(2,1)))/ C / (ZX(4,1)-ZX(3,1)) C A1(2)=(PHI(ZX(1,2))+PHI(ZX(4,2))-PHI(ZX(3,2))-PHI(ZX(2,2)))/ C / (ZX(4,2)-ZX(3,2)) C C SUM OVER TERMS IN GRID TRANSPARENCY APPROXIMATION C DO 2500 I=1,2 DO 2450 J=1,2 C C CALCULATE RESULT OF ANALYTICAL INTEGRATION OVER VX C AX(I)=UPS(ZX(1,I),ZX(2,I),ZX(3,I),ZX(4,I)) C C CALCULATE RESULT OF ANALYTICAL INTEGRATION OVER VY C AY(J)=UPS(ZY(1,J),ZY(2,J),ZY(3,J),ZY(4,J)) C C ASSEMBLE INTEGRAND FOR INTEGRATION OVER VZ C D(I,J)=-U(1)**2*AC(I)/(VZ**2+AC(I))-U(2)**2*AC(J)/(VZ**2+AC(J)) IF (D(I,J) .LT. -20.0E0) GO TO 2050 D(I,J)=CC(I)*CC(J)*EXP(D(I,J))/SQRT(AA(I)*AA(J)) GO TO 2051 2050 D(I,J)=0.E0 2051 CONTINUE C C ADD TO SUM FOR INTEGRAND (EXCEPT MAXWELLIAN FACTOR) C G=(VZ/S)**2*D(I,J)*AX(I)*AY(J)/4.E0+G 2450 CONTINUE 2500 CONTINUE C C ADD TO SUM OF CONTRIBUTIONS FOR NUMERICAL INTEGRATION OVER VZ C (INCLUDING MAXWELLIAN FACTOR) C CURENT=CURENT+VZ*EXP(-X1)*G*DVZ C C FILL ARRAY FOR UPPER MODULATOR STEP INTEGRATION, IF APPROPRIATE C 2590 IF (JJ .EQ. NL(NCN) .AND. MODE .EQ. 1) CRR(NCN)=CURENT*CONST IF (JJ .EQ. NM(NCN) .AND. MODE .EQ. 2) CRR(NCN)=CURENT*CONST 2600 CONTINUE C C FILL ARRAY FOR LOWER MODULATOR STEP INTEGRATION C CRNT(NCN)=CURENT*CONST 5000 CONTINUE C C COMPUTE CURRENTS BY TAKING DIFFERENCE BETWEEN ADJACENT MODULATOR C STEPS C DO 5110 JJ=NC1,NC2 5110 DIST(JJ)=(CRNT(JJ)-CRR(JJ+1)) RETURN END