July 5 2019 the program to do the L-mode or M-mode in the d cup as per jdr's request the main routine main.f sets the time, the velocity, the thermal speed, and the density and sets whether you are doing an L mode (MODE = 1) or M mode (MODE = 2) in calling roll.f. In either case (L or M) roll.f returns a single current, the sum of currents in channels ICHN1 to ICHN2. If ICHN1 = ICHN2, roll.f returns the current in channel ICHN1 to reset the time velocity, density, thermal speed, MODE, ICHN1 or ICHN2 change the values in main.f, save, and then type "make" on faraday. That will use the file Makefile to recompile whatever code needs to be recompiled. Then to get the code to run with these parameters type "test > outputfile " The routine roll.f does the dcup current response at angle "angle" from the current roll orientation. This is the simulation that we use to help interpret the roll data in the interstellar medium, see Section 9 of VI-PLS. In the main.f. program we set the time of the roll, the mode (L or M), and the channels we sum over (usually 1 through 1 for the L mode and 1 through 8 for the M mode). The example output in output is for the M mode summing over channels 1 through 8. We step through the roll in five-degree increments. Note: even though some of the names of the routines here are identical to names of routine in software_v_01/mjsanl/code, do not assume these routines are identical. The file v2_shortsedrPredict is a binary version of the Voyager 2 predict, we read it using the option (in phase4.f) open(33, file= * 'v2_shortsedrPredict', * form='unformatted', convert='big_endian')